2. Installation accessory
2. Prepare the following assemblies on the site.
No.
Name
1 Switch box
2 Wiring Tube(Insulating
Sleeve and Tightening
Screw)
Precaution of installing the wire controller
1. This manual provides the installation method of wired
controller. Please refer to the wiring diagram of this
installation manual to connect the wire controller with
indoor unit.
2. The wired controller works in low voltage loop circuit.
Forbid to directly contact the cable of high voltage
above,like 115V, 220V,380V, and don't wire this kind
of wire in the said loop; wiring clearance between
configured tubes should be at the range of 300~500mm
or above.
3. The Shielded wire of the wired controller must be
grounded firmly.
4. Upon finish the wire controller connection, do not
employed tramegger to detect the insulation.
3-GB
Qty. (embeded
into wall)
1
1
Specification
(only for reference)
Remarks