Hang the heater from the hooked edge of the mounting bracket.
9.
Connect the power supply wires to the wires in the unit - black
(L1) and white (L2). Ground wire should be secured to the green
wire provided inside of the heater.
WARNING: All wiring must be installed by a certified electrician
according to the electrical safety. The ceiling heater must be ground-
ed in accordance with all national and local building codes.
10. Replace the wiring compartment cover and replace with the 2
screws.
11. Locate and secure the external temperature sensor to the ceiling
with the provided wire clips. It is recommended that the sensor
wire be fully extended for optimal control of the room tempera-
ture. (Figure 1)
12. Swing the heater upwards to secure the opposite side of the
heater to the bracket and secure with previously removed
screws.
13. Replace the grill box.
WARNING: TO PREVENT THE RISK OF FIRE OR INJURY, DO
NOT OPERATE THE HEATER UNLESS IT IS FULLY ASSEM-
BLED.
Initial Set Up
After the unit has been installed, calibration of the unit to the area
will be required. This can be done by closing all doors and windows
to the room and turning the unit ON. When the unit is initially turned
on there is a 28 minute period of calibration of the unit where the
software runs at full power for 20 minutes, then runs for 8 minutes to
cool the heater down.
If the unit is relocated or the size of the area that it is installed in chan-
ges, it is recommended that the unit be reset to the factory default to
allow the unit to recalibrate.

Factory Default

1. Press and hold the V for 3 seconds. Both the
will begin to flash.
2. Within 5 seconds press ✚, then ✚, then –, then –, then V,
then –.

Wiring Diagram

CONTROL PCB
K1
POWER PCB
Figure 3
A
F
H
D
B
E
C
2
SENSOR
T3
M
T4
CUTOUT
L1
T1
L2
T2
G
CUTOUT
A - Setting/Temperature Display
B - Comfort Setting Icon
C - Economy Setting Icon
D - Set Back Temperature Setting
E - Synchronized Icon
F - Lock Icon
G - Decrease Button
H - Increase Button
I - Menu Button
I
G
Operation Instructions
WARNING: This heater is factory pre-wired for operation with the
built-in thermostat. THIS HEATER IS NOT TO BE USED WITH A
REGULAR WALL THERMOSTAT.
CAUTION: This heater must be properly installed before it is used.
The RCH is designed with heating elements that will turn on and off
based on the built-in temperature sensor to maintain a constant room
temperature.
!
NOTE: The element retains heat after shutdown, there is a built
in cool down period of 5 minutes before the fan shuts off completely.
Manual Controls
(See Figure 3 for display reference)
When power is first supplied to the RCH the Set point Temperature will
flash in the temperature display area. At any time either the ✚ or – but-
ton can be pressed to have the temperature set point displayed again.
A. Setting/Temperature Display
The RCH is designed to control the temperature of a room from 41-
86°F (5-30 °C). By pressing the ✚ or – will increase or decrease
the desired temperature for the room to be heated by 0.5° (in either
°C or °F).
When adjusting the Set point Temperature the display will switch
back to display the ambient temperature after 5 seconds.
!
NOTE: The unit can be set to run continuously as a fan by setting
the temperature at 41 °F (5 °C). At this temperature the heater will
not turn on.
!
NOTE: Pressing the ✚ and – at the same time will toggle be-
tween °C and °F.
B. Comfort Setting
and
icons
The Comfort Setting icon will be displayed when the heater is in nor-
mal operation based on the Set point Temperature for the room.
!
NOTE: Either the
on the setting being used.
C. Economy Setting
The Economy Setting can be used to change the Set point Temper-
ature for a user determined period of time. By pressing the V the
Economy Setting will be enabled - signified by the icon flashing. After
the Set Back Temperature has been set, the icon will become solid
after three seconds and the Set Back Temperature will be enabled.
To return back to the Comfort Setting press the V button. The
will disappear and the
D. Set Back Temperature Setting
The Set Back Temperature Setting is used during periods when the
Economy setting feature is active. This temperature adjustment can
be set by pressing the V followed by the ✚ or –.
E. Synchronized Icon
The RCH features CONNEX
with Dimplex CONNEX
connectivity and comfort (a single zone controller is included). CON-
NEX
controllers are available to control one or multiple CONNEX
TM
series heaters within a 50' (15 m) radius. In order for the controller
to have this function the RCH and the controller will need to be syn-
chronized. To do this:
1.
On the RCH press and hold the V button for 3 seconds, both the
and
2.
Press the – , ✚ and then V, on the RCH.
3.
Within
CONNEX
or
icon will always be visible, dependent
icon will appear.
, a wireless technology that works
TM
controllers to provide simple whole home
TM
icons will begin to flash.
10
seconds
press
any
Controller.
TM
icon
TM
button
once
on
the