Wiring
Terminal Designations
L
Heat pump system monitor
C
Common wire from secondary side of
cooling transformer, if 2 transformers
W2
2nd stage heat relay (heat pump
(AUX)
auxiliary, emergency heat)
W
1st stage heat relay (changeover valve
(O/B)
for heat pumps)
U1
Terminal for indoor air quality products
(humidifier, dehumidifier, ventilator)
U2
Terminal for indoor air quality products
(humidifier, dehumidifier, ventilator)
Wiring Configurations
Two stage furnace and air-conditioning
C
Common wire (optional)
W2
Heat relay (stage 2)
W
Heat relay
G
Fan relay
Y2
Compressor contactor (stage 2)
Y
Compressor contactor (stage 1)
R
Power
8
K
Optional C-wire adaptor
G
Fan relay
Y2
2nd stage compressor contactor
Y
1st stage compressor contactor
R
Heating power. Connect to
secondary side of heating system
transformer
Rc
Cooling power. Connect to
secondary side of cooling
system transformer
Notes
• Thermostat C wire
is optional for this
application. C wire
required if Homekit
is used.
• Set the R Jumper
Switch on the wall
plate to R