Programmable Multiband Amplifier
TMB 200 & TMB 200S
AGC
p
AGC
Menu
p
Auto
Auto Level
Menu
117
p
•
Unit in standby mode, push a button to reach the SETTINGS/Config menu.
Press the button until the display shows the AGC menu.
•
•
Press Menu button to enter the function
•
Press the buttons + or - to select on or off
•
Confirm by pressing Menu
IMPORTANT!
•
AGC: The unit memorizes the average output level. A variation of ± 1 dB triggers the function
and compensates the variation within gain and attenuation limits
•
AGC mode hides all other menus. To modify the parameters, switch the AGC mode to OFF
Auto level
Unit in standby mode, push a button to reach the SETTINGS/Config menu.
•
•
Press the button until the display shows the Auto menu.
•
Press Menu button to enter the function
•
Press the buttons + or - to select the output level value
•
Confirm by pressing Menu
IMPORTANT!
•
The unit memorizes the selected output level, the function try to reach the value within input,
gain and attenuation limits.
Note: Setting of VHF level is not automatic.