SPECIFICATIONS
Voltage ....................................................................... 120VAC, 60HZ
Load (Single Pole Circuit)
Incandescent or fl uorescent lamp ........................... 0 – 600 Watt
Fan Motor ............................................................................1/6HP
Time Delay...............................................1, 5, 10, 20, 30, 60 minutes
Environment .......................................... Residential Indoor use only
Operating Temperature ..............................32° to 131°F (0° to 55°C)
Humidity ....................................................95% RH, non-condensing
Tools Needed
Insulated Screwdriver
Wire Strippers
DESCRIPTION AND OPERATION
The RT-50 is a time switch that turns OFF the connected light or fan when the
selected time expires. The light behind the ON/OFF button illuminates while the
switch is OFF. One of the time button indicators is always lit to indicate the last
used timer.
Manual ON
Turn ON the connected light or fan by pressing the desired time button, or the
ON/OFF button. If you press the ON/OFF button, it activates the timer that was
last used.
Manual OFF
While a timer is active, you can press the ON/OFF button to turn OFF the
connected light or fan without delay.
Changing the selected time
If you decide that you need more or less time than you originally selected, restart
the time switch by pressing the button that matches the amount of time you think
you'll need.
Call 888.817.0571 for Technical Support
RT- 50
Time Switch
7- Button Preset
6 time selection buttons with
activation indicator lights
Lighted Switch
ON/OFF Button
Santa Clara, CA 95050

Publicidad

Tabla de contenido
loading

Resumen de contenidos para LEGRAND Watt Stopper RT-50

  • Página 1 Please read all instructions before installing RT- 50 Time Switch 7- Button Preset 6 time selection buttons with activation indicator lights Lighted Switch ON/OFF Button SPECIFICATIONS Voltage ............... 120VAC, 60HZ Load (Single Pole Circuit) Incandescent or fl uorescent lamp ......0 – 600 Watt Fan Motor ................1/6HP Time Delay..........1, 5, 10, 20, 30, 60 minutes Environment ..........
  • Página 2 INSTALLATION & WIRING WARNING Disconnect power to the wall switch box by turning OFF the circuit breaker or removing the fuse for the circuit before installing the RT-50, replacing lamps, or doing any electrical work. 1. Prepare the switch box. HOT (power from circuit box) After the power is turned OFF at the circuit...
  • Página 3: Warranty Information

    WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of fi ve (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profi...
  • Página 4: Especificaciones

    Por favor leer todas las instrucciones antes de realizar la instalación RT-50 Interruptor Temporizado Preajuste de 7 Botones 6 botones de selección de tiempo con luces indicadoras de activación Botón iluminado de ENCENDIDO/APAGADO ESPECIFICACIONES Voltaje ............... 120VAC, 60Hz Carga (Circuito unipolar) Lámparas incandescentes o fl...
  • Página 5: Instalacion Y Cableado

    INSTALACION Y CABLEADO ADVERTENICA Desconecte la corriente que alimenta la caja de conexiones apagando el disyuntor (breaker) o removiendo el fusible para el circuito correspondiente antes de instalar el RT-50, reemplazar luces, o realizar cualquier trabajo eléctrico. LINEA/FASE (proveniente de la 1.
  • Página 6: Identificacion Y Resolucion De Problemas

    (5) años. No existen obligaciones o responsabilidades por parte de Watt Stopper / Legrand por daños ocasionados por o en conexión con el uso o desempeño de este producto u otros daños indirectos en materia de pérdida de propiedad, ventas o ganancias, o...

Tabla de contenido