Make sure that the motor
turns in the suitable way when
starting the equipment.
Motor
Fig. 6.1
Motor turn way
Fig. 6.2
Wire identification for mains
connection.
7. Temperature controller
8. Safety temperature controller
1. Main and motor switch
2. Heating switch
5. Heater starting up light
6. Heater overtemperature alarm light
J
.P. SELECTA s.a.
You must try different combination beetwen wires Black, Brown and
Grey until you find that the motor turns in the right way (See figures
6.1 and 6.2).
Make sure that the motor turns in the suitable way when
switching on the oven.
If the motor turns the wrong way, this will excessively warm
and its life will shorten.
Ground wire
The plug must have a ground wire.
The oven must be connected to an electrical supply provided with an
earth wire.
Do not use nor start up the oven if its ground wire is not grounded to
the installation.

7. Operation

Door

7.1 Control Panel

1 . Main and motor switch: It is used as main switch and also to
start the fan motor.
2 . Heating switch: It switches the heater on.
3 . Motor starting up light (green): It indicates that the motor is
ON .
4 . Motor overtemperature alarm light (red): It indicates that the
Blue: Neutral
motor has stopped due to overtemperature.
5 . Heater starting up light (green): It indicates that the oven's
Black: Phase I
heater is ON.
Brown: Phase II
6 . Heater overtemperature alarm light: It indicates that the
Grey: Phase III
heater has stopped due to overtemperature.
7 . Temperature controller: It establishes the operating
Yellow/green:
te mpe ra ture.
Ground
8 . Safety temperature controller: It establishes the safety
te mpe ra ture.
Ctra. NII Km 585.1 Abrera 08630 (Barcelona) España
e-mail: selecta@jpselecta.es - http://www.jpselecta.es
(Sujetas a modificaciones sin previo aviso)
3. Motor starting up light
4. Motor overtemperature alarm light
Tel (34) 93 770 08 77 Fax (34) 93 770 23 62
Pag.: 12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2001406

Tabla de contenido