6 ALARM MANAGEMENT

The stove is supplied with an automatic status control
system. When a system anomaly is detected, an error
message is displayed on the control panel screen ( g. 5.1 .
CODE
E 0 0 4
Communication error
NO CONNECTION
E 1 0 1
Start-up failure
NO IGNITION
E 1 0 2
Temperature of fumes is too low
E HAS.TEMP.
E 1 0 3
Flue gas fan error
E HAUST FAN
E 1 0 4
Black-out
BLACK OUT
E 1 0 5
Supply water probe alarm
WATER PROBE
E 1 0 6
Return water probe alarm
RETURN PROBE
E 1 0 8
Safety error
THERMAL
E 1 0 9
Pressure error
DEPRESS
E 1 1 0
Temperature probe malfunction
ROOM PROBE
E 1 1 1
Exhaust probe malfunction
SMOKE PROBE
E 1 1 3
Fault in the burn pot shaking system
BURN POT
B LO CK
After you have checked the message type and resolved the problem, you can reset the warning by holding down
the ON button for a little while.
At this point you can restart the stove.
DESCRIPTION
E 1 0 8
POSSIBLE CAUSES
The wire linking the motherboard and the control panel
has been interrupted or disconnected
Hopper is empty
Pellet quality
Ignition system damaged
Dirty brazier
Possible ignition failure
Check the pellet level in the hopper and that brazier is
clean and in the correct position.
Check that the door and the ash box are properly closed.
Flue gas fan is disconnected or faulty
Power failure when the stove is operating.
Water probe disconnected or defective
Return water probe disconnected or defective
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
Dirty ue
Burn pot gaskets worn
Inadequate combustion air intake
Faulty air probe
Faulty exhaust temperature probe
Possible electromechanical component fault
31
g. 6.1
g. 6.2