LaserLiner AutoCross-Laser 2 XP Manual Del Usuario página 15

Ocultar thumbs Ver también para AutoCross-Laser 2 XP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
AutoCross-Laser 2 XP / AutoCross-Laser 2 XPG
Preparing the calibration check:
It is possible for you to check the calibration of the laser. To do this, position
the device midway between 2 walls, which must be at least 5 metres apart.
Do this by turning the unit on, thus releasing the transport restraint (cross
laser on). Please use a tripod.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2.
You now have a horizontal reference between points A1 and A2.
1.
A1
2.
Performing the calibration check:
3. Position the device as near as possible to the wall at
the height of point A1.
4. Turn the device through 180° and mark point A3.
The difference between points A2 and A3 is the tolerance.
3.
A1
4.
When A2 and A3 are more than 2 mm / 10 m apart, an adjustment
!
is necessary. Contact your authorised dealer or else the UMAREX-
LASERLINER Service Department.
A2
A2
A2
A3
A2
A3
15
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Autocross-laser 2 xpg

Tabla de contenido