Connect the power cables directly to the battery or a chassis part that will provide an effective
ground path. Protect the installation with four 15 A fuses situated as close as possible to the battery
connection, as shown in the wiring diagrams at the end of this manual.
The lights or warning lightbars are supplied with a wiring diagram. These diagrams usually include
the light control switches. In the case of this siren model, the switches will be replaced by relays situated
in the amplifier. The positive power cable to the light or lightbar would be connected directly to the
amplifier connector.
SPECIFICATIONS
Input voltage:
Temperature range:
AMPLIFIER:
Operating current:
Frequency range:
Cycle repetition:
Voltage output:
Radio signal input:
Harmonic distortion:
Band width +/- 3dB:
Level radio signal:
Output power:
LIGHTS:
Light controls:
Lamp failure detection:
(see APPENDIX 1)
The equipment is originally supplied with the internal bridges set to "non-detection of lamp failure".
SAFETY INSTRUCTIONS FOR THE INSTALLER
It is extremely important to follow all the instructions enclosed with the equipment. Below are listed
other instructions which must also be taken into account:
12 Vdc (nominal)
(from 11 to 15.5 Vcc)
- 30ºC to + 60ºC
Siren: 10 A maximum (with one speaker)
600 - 1350 Hz
WAIL
YELP
TWO TONES
60 V pp
6% (35 W, 1000 Hz)
90 Hz - 28 KHz (at 1000 Hz)
4 V max.
100 W
Main warning lights: 20 A max. (two lines 10 A + 10 A)
Auxiliary lights: maximum 10 A
Only main warning lights
Can be selected: -non-detection of lamp failure
-failure detection with only one lamp installed
-failure detection with two lamps installed
-failure detection with power supply installed
17
12 cycles/min
170 cycles/min
33 cycles/min