Flue; Door Closing Pressure; Chimney Connector; Pre-Utilisation Check - FRANCO BELGE SAVOY MK2 Presentación Del Material Y Instrucciones Para El Instalador Y Instrucciones Para El Usuario Y Pieza

Estufa de leña
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

"SAVOY MK2" - model : 134 08 09

2.7 Door closing pressure

Figure 6
The closing latch rotates around a pressure screw
positioned cam.
-
Remove gently the ceramics rope
-
Loosen pressure screw 1.
-
Turn cam 2 to desired position.
-
Tighten pressure screw 1.

2.8 Chimney connector

The connection to flue must be carried out according to
local building regulations.
The appliance must be installed as close as possible to
the chimney.
The connector pipe must be approved for installation
with combustion products (either 24 ga. Black painted
or blued steel or 316 grade 20 ga. Stainless steel or 1
mm vitreous enamelled steel).
Pipe diameter must not be less than the appliance
spigot diameter.
The connection can be either vertical or horizontal. For
horizontal connections, avoid right angle bends.
The join between the connection pipe and the
stovepipe, and the flue, must be leak tight.
For the premises equipped with a mechanical
controlled ventilation, the airtightness has to prevent
the exhauster drawing out the smokes from the
exhaust gas pipe.
The connection pipe and any draught stabiliser must
have access for cleaning.
The spigot should be connected to a minimum of
125 mm flue system and in that case the appliance is
capable of burning untreated wood and recommended
solid fuels.
6
1
1 - Pressure screw
Figure 6 - Door closing pressure

2.9 Pre-utilisation check

-
Check that the seals of the smoke-line are in good
condition. Check that the door closes correctly. Check
that the glass is not damaged. Check that the smoke
passages are not obstructed by packaging or
removable parts. Check that all removable parts are
correctly installed.
Note : The rope seals should be checked on a regular
basis as they are normal replacement parts.

2.10 Maintenance of the Chimney

Very important : In order to avoid any incident
(chimney fire, etc...), maintenance tasks must be
carried out regularly. If the appliance is regularly used,
the chimney should be swept several times per year,
together with the stovepipe connection section.
If the chimney catches fire, you must cut off the flue
draught, close the doors and windows, hatches and
keys and call the Fire Brigade without delay.
DO NOT OPEN THE DOOR OF THE APPLIANCE
(OR AIR INLET) UNDER ANY CIRCUMSTANCES
Installation instruction
2
2 - Cam
Technical manual "1274"