"SAVOY MK2" - model : 134 08 09
3.2 Lighting
Figure 7
-
Slide the air control (# B and C).
-
Open the front door and lay firelighters or rolled up
newspapers on the grate with a reasonable quantity, if
necessary, of dry kindling wood. Place 2 or 3 small
logs on top.
-
Light the newspaper or firelighters using a long taper
and close the front door.
-
When the fire is burning fiercely, add further logs of a
diameter up to 10 cm.
-
When the stove body is very hot, close the lower air
control (# C).
-
The burning rate can now be adjusted by moving the
top air control to the left (# B).
Experience will show you which settings are best for
your situation.
3.3 Operating procedure
The appliance must function with the door properly
closed, the burning rate being controlled in using the
secondary air regulation flap (rep. B).
Experience will show you which settings are best for
your situation.
The airwash system works with the top airslide. When
the top airslide is full open the system works at its
strongest efficiency.
The more closed down the airslide is, the less effective
the airwash will be (when shut down completely, the
airwash system can not function).
•
Loading the fuel
-
The door should be opened slowly, avoiding a sudden
rush of intake air, so that smoke does not escape into
the room.
-
The logs must be placed on the glowing embers.
-
For a briskly burning fire, there should always be at
least two logs in the fire. The fire will burn better if
there are several logs.
-
For a slower burning fire (for example, at night), select
larger logs.
-
After loading the firebox, close the main door (rep. A,
figure 7, page 7).
3.4 De-ashing
-
Ashes must be removed regularly.
-
Ashes must never be allowed to pile up to the grate.
The grate would not be cool down and could rapidly be
damaged.
-
Empty the ashes when the appliance is cold.
-
Remove the ash drawer using the tool provided.
-
Empty the ashes carefully with regard to the live
embers.
8
3.5 Maintenance of the Chimney
Very important ! In order to avoid any incident
(chimney fire, etc...), maintenance tasks must be
carried out regularly.
If the appliance is regularly used, the chimney
should be swept several times per year, together
with the stovepipe connection section.
If the chimney catches fire, you must cut off the flue
draught, close the doors and windows, hatches and
keys and call the Fire Brigade without delay.
DO NOT OPEN THE DOOR OF THE APPLIANCE
(OR AIR INLET) UNDER ANY CIRCUMSTANCES.
The chimney must be serviced and cleaned by a
specialist.
3.6 Maintenance of the stove
•
The appliance must be cleaned regularly, together with
the connecting pipe and the flue pipe.
•
Open the door and remove all deposits in the firebox
and clean the removable fire grate.
•
Cleaning of the glass door can be done with a soft cloth
dampened with water and vinegar or potassium ; this
must be done when the appliance is cold ; then rinse
with clear water. Do not use abrasive cleaners.
•
The "vitroceramic" glass will resists to temperatures of
up to 750 C. Should the glass break due to misuse, it
must be replaced by the manufacturer own product.
•
All the casing parts can be cleaned using a soft cloth
either dry, or slightly damp. In case of condensation or
water splashes clean the parts before they dry out.
•
Check that there are no obstructions before relighting
after a long period of disuse.
•
The appliance must not be used with a flue serving
several appliances.
•
Keep the grates ventilation free of any obstruction.
•
The baffle plates should be removed regularly and any
ash or deposits cleaned away.
•
Ashes must not be allowed to build up.
•
The door rope seals should be checked annually and
replaced when required.
3.7 Safety advice
This appliance produces heat and may cause severe
burns if touched.
The stove may still be HOT even when the fire has burnt
out.
KEEP CHILDREN AWAY.
A FIRE GUARD IS ADVISABLE TO PROTECT
CHILDREN THE ELDERLY AND INFIRM.
Instructions for user
Technical manual "1274"