WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
WARNING:
TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE,
FLUORESCENT LIGHTING, A MOTOR- OR A TRANSFORMER-OPERATED APPLIANCE.
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
CAUTION:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.
CAUTION:
USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY.
GANGING/DERATING:
When two units are ganged together, use no more than 500W load on each device. When three or more units are ganged together, use no more than a 400W load on each unit.
FEATURES
• No RFI filter for radio/TV interference
• Fits standard wall boxes
INSTALLATION
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
2. Remove existing wallplate and switch, if applicable.
3. Remove 5/8" (1.6 cm) of insulation from each circuit conductor. Make sure the ends of wires are straight.
4. Connect wires per WIRING DIAGRAM as follows: Twist strands of each lead tightly together and, with circuit conductors, push firmly into appropriate wire connector.
Screw connectors on clockwise making sure no bare conductors show below the wire connectors. Secure each connector with electrical tape.
5. Installation may now be completed by carefully positioning all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting screws supplied.
Attach wallplate and knob.
6. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper
use for five years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for
a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
AVERTISSEMENT : POUR ÉVITER LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURE MORTELLE, COUPER LE COURANT AU FUSIBLE OU AU
DISJONCTEUR ET S'ASSURER QUE LE CIRCUIT SOIT BIEN COUPÉ AVANT DE PROCÉDER À L'INSTALLATION.
AVERTISSEMENT : POUR ÉVITER LA SURCHAUFFE OU L'ENDOMMAGEMENT ÉVENTUEL DE CE DISPOSITIF ET D'AUTRES APPAREILS RACCORDÉS, NE PAS
L'INSTALLER POUR COMMANDER UNE PRISE, UN LUMINAIRE FLUORESCENT, OU UN APPAREIL MOTORISÉ OU À TRANSFORMATEUR.
AVERTISSEMENT : INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L'ÉLECTRICITÉ EN VIGUEUR.
MISE EN GARDE : À DÉFAUT DE BIEN COMPRENDRE LES DIRECTIVES SUIVANTES, FAIRE APPEL À UN ÉLECTRICIEN.
MISE EN GARDE : N'UTILISER CE DISPOSITIF QU'AVEC DU FIL DE CUIVRE OU PLAQUÉ CUIVRE.
Single Pole (1 Location) Rotary Dimmers
Cat. No. 705 - 600W (Push On/Off)
INSTALLATION INSTRUCTIONS
Wiring Diagram - Single Location Control Application
Schéma de câblage : Fonctionnement pour commande à un emplacement
Diagrama de Cableado : Applicación de control en una sola ubicación
Hot (Black)
Actif (Noir)
Fase (Negro)
Black/Noir/Negro
Line 120VAC, 60Hz
Ligne 120 V.c.a., 60 Hz
Línea 120VCA, 60Hz
Neutral (White)
Neutre (blanc)
Neutro (Blanco)
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
For Technical Assistance call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
Gradateurs rotatifs unipolaire (1 emplacement)
Nº de cat 705, 600 W (à bouton poussoir)
Cat. No. 700 - 600W
120VAC, 60Hz
Dimmer
Gradateur
Atenuador
Black/Noir/Negro
Green Ground
Terre vert
Verde a Tierra
Nº de cat. 700, 600 W
120 V c. a., 60 Hz
DIRECTIVES
Black
Noir
Negro
Load
Charge
Carga
White
Blanc
Blanco
PK-A3110-10-02-2A
ENGLISH
FRANÇAIS

Publicidad

loading

Resumen de contenidos para Leviton 700

  • Página 1 LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date.
  • Página 2 Leviton garantit au premier acheteur, et uniquement au crédit dudit acheteur, que ce produit ne présente ni défauts de fabrication ni défauts de matériaux au moment de sa vente par Leviton, et n’en présentera pas tant qu’il est utilisé de façon normale et adéquate, pendant une période de cinq ans suivant la date d’achat. La seule obligation de Leviton sera de corriger lesdits défauts en réparant ou en remplaçant le produit défectueux si ce dernier est retourné...

Este manual también es adecuado para:

705