Filling
IMPORTANT: Always make sure the pressure is
released from the tank before filling or servicing.
1. Pull up on the knob of the pressure release
valve until all the pressure is released from the
tank. (See Figure P.)
2. Turn the pump handle counterclockwise to remove
the pump (See Figure R).
3. Fill the tank to the desired level. See fill markings
on side of tank. When mixing muriatic acid or acid
stain with water, always slowly add acid to water to
minimize heat generation and spattering. NEVER
ADD WATER TO ACID. A reaction can occur causing
the liquid to expand rapidly and splash out of the
sprayer. (Always refer to chemical manufacturer for
proper mixture).
4. Install the pump into the tank opening and turn
clockwise until tightly sealed against the tank
(See Figure S).
Pressurizing
1. Make sure shut-off lock is not engaged. (If shut-off lock is engaged while pressurizing, the unit
will immediately start spraying).
2. Push down on the handle and turn counterclockwise to unlock the handle (See Figure T-1T).
3. Pressurize the sprayer by pumping the handle in a smooth up and down motion (See Figure T-2T).
4. Push down on the handle and turn clockwise to lock the handle into the pump (See Figure T-3T).
1T
SM II Shut-off Spraying and Locking
1. Direct nozzle away from you and squeeze shut-off
lever to begin spraying.
2. For continuous spraying, squeeze lever and rotate
lock (See Figure U).
3. Unlock if needed and release shut-off lever to stop
spraying. (See Figure V)
4. Turn the nozzle tip to adjust the spray pattern.
OPERATING INSTRUCTIONS
2T
Figure T
Figure P
Figure R
3T
Figure U
Figure V
Figure S
Page 4