Terminal Blocks
TERMINAL BLOCK 1
DESCRIPTION
+12V (RED)
- (BLK)
BUS (GRN)
BUS (YEL)
SET ∗
RC ∗
(REMOTE
CONTROL)
IMPORTANT:
Turn DIP switch 7 "OFF" after installation and when leaving the site for security reasons. This will
prevent unauthorized use of a remote control unit that may be used to disable the detector.
∗
Not relevant in BUS mode
TERMINAL BLOCK 2
AM/FAULT
TAMPER
ALARM
Power supply positive (+) input voltage
Common to control panel power supply
Used for data communication with the ProSYS
Used for data communication with the ProSYS
Used to remotely SET/UNSET the detector.
When an activation signal (see RC/SET Activation jumper for settings) is applied to the
SET input of the terminal block:
AM will be disabled (if the AM DIP switch 5 was previously ON)
MW module is enabled (if the Green Line DIP switch 3 was previously ON).
Removing an activation signal will cause a Self Test (if the Remote Self Test DIP switch
4 was previously OFF).
Used to enable/disable the remote control communication, only when DIP switch 7 is
"OFF".
When an activation signal (see RC/SET input jumper for settings) is applied to the RC
input of the terminal block, Remote Control will be enabled.
Note: DIP switch 7 "ON" constantly enables RC communication.
DESCRIPTION
Normally closed output
The AM/FAULT output opens in the following events:
Detector is masked (ALARM also opens in this case)
Self Test failed
Input voltage is low (6VDC-8VDC)
Normally closed output
Normally closed output
Industrial LuNAR DT AM Grade 3 Installation Guide
19