4.2.
Use as a Wired
Remote
Controller
(Using the MA Remote
Controller)
1. Be sure to set the "Auto
Heating/Cooling
Display
Setting"
of the MA remote controller
OFF before use. When the
setting
is turned ON, the remote controller
display
may differ
from the actual operating
status of the unit.
• For details on the"Auto
Heating/Cooling
Display Setting,"
refer to the MA remote controller
instruction
manual.
2. A test run cannot
be initiated
using the test run switch
on the MA remote controller.
3. The horizontal
vanes on the unit cannot
be operated
using the louver switch.
4. The range of room temperature
indication
is between
10°C and 38°C.
Indoor unit
Interface unit O
TB580
]
Remote control cord that came with
the MA remote controller O
_
A remote controller
(PAR-21 MARl
* PAR-20MAA cannot be used
with this interface.
• SW500 does not have to be set.
• SW501 :
SW501- No. 1-4: Refrigerant
address
• Set this switch when multiple indoor units (and interfaces) are connected to a MA remote controller.
• Always start the refrigerant address at"0".
Even when connecting
multiple outdoor units, set a different refrigerant address for each indoor unit.
d
Refri_
addre
)
\
()
()
Refri _ )erant
addr_ _s 1
/\
(_) Outdoor unit
)_
(D Multi outdoor units
(_ Indoor unit
(_ Interface
0 MA remote controller
®
I
®
I
®
Refrigerant
address '2"
/\
[
Refri_
addre
)
Refrigerant
address
2
,L
15
SW501- No. 5-6
M series
No. 5 and 6 should normally be set to OFF.
Under the following conditions,
however, they should be switched to ON.
Only turn this ON when the indoor units in the same group include models where the MA remote controller and
indoor unit are directly connected.
--,,-
Set them to ON only when using the room temperature sensor installed in the MA remote controller.
This can be switched when an accurate room temperature cannot be detected by the air conditioner unit.
MSZ-GA and MSZ-FA Series models can not use a room temperature sensor on their MA remote controllers.
(Some M series models will not allow the use of the MA remote controller room temperature
sensor.)
P/S series
Set SW501 -No. 5 to ON
Set SW501 -No. 6 to OFF