Descargar Imprimir esta página

Mitsubishi Electric MAC-397IF-E Para El Instalador página 7

Ocultar thumbs Ver también para MAC-397IF-E:

Publicidad

• SW502:
• Set t his switch based onthe functions
ofthe Indoor Unit connected
tothe interface.
• See the Page 1 2 table a nd set t he switch after c hecking
the functions
using t he wireless remote control that c ame w ith the
Indoor Unit.
4.3.
Remote
Control
(Turning
Indoor Unit On and Off from the Contact
Point)
• You can turn Indoor Unit on and off using an on/off switch like a light switch.
• Connect the supplied lead wires (6) O to the connector CN591 on the interface board.
• Wire the remote control components,
including the switches, at the installation site.
• Please use extension cords with reinforced insulation.
Indoor unit
Interface unit O
CN591
* Lead wires (6) @
Switch (contact point a)
about 10 mA) O
Extend the cord using the extension cord O
at the installation site.
100 m max.
• When the switch contact point is closed (ON), the air conditioner will turn on, and when the switch contact point is open (OFF),
the air conditioner will turn off.
When connecting the connector and the lead wire, connect them using a closed end connector as shown below.
Extension cord O
Closed end connector
• sw5oo
ON
r;ll l;ll;ll'll;ll;ll;1
1
2
3
4
5
6
7
8
k__
_Y
-,,f
Setting required
• SW501 and SW502 do not have to be set.
7

Publicidad

loading