6.1.4
DISPLAY
Lingua
Unità di misura
Versione
Display
The Contrast parameter allows for regulation of LCD contrast. The brightness parameter allows for regulation of the brightness of the LED of the
display's backlighting system. Values, given as percentage values, are independent.
6.1.5
USB
Usb
Test
Firmware 1.00
You can use a USB flash drive to:
- save the configuration and settings of DATA-MATE;
- save tank calibration;
- upload configuration and tank calibration settings previously saved.
Always keep a backup copy of this information on an external digital support. By uploading configuration (CONF.CFG) or calibrated tank (TANK.TNK)
data, you will overwrite all data currently saved on the DATA-MATE.
6.1.6
TEST
Usb
Test
Firmware 1.00
By means of this function, you can test if sensors have been correctly installed.
With the sprayer off and the tank empty, connected pressure and level sensors must provide a default value of approximately 4 mA. To test pulse
input sensors (flowmeter and speed), activate the sprayer (flow rate and speed recording). The signals's frequency must change with respect to the
initial 0 Hz recorded.
200.1012.15
OPZIONI
OPZIONI
OPZIONI
Contrasto
Luminosità lcd
Salva configurazione
Carica configurazione
Salva cisterna
Carica cisterna
Pressione
Livello
Flussometro
Velocita'i
8 / 22
DISPLAY
50 %
50 %
USB
TEST
0.00 mA
0.00 mA
0.0 Hz
0.0 Hz
Rev. 01 01/02/2016