6.3.2
AUTOMATIC CALIBRATION WITH A FLOWMETER
To speed up the tank calibration operations, you can use the flowmeter installed downstream to the tank's emptying tap. First of all, you must set the
flowmeter's pulse/litre value in the SENSORS=>FLOWMETERS menu (see § 6.2.3). The flowmeter can be connected to the AUX or FLOWMETER1
input of DATA-MATE.
CALIBRAZIONE
Manuale
Automatica
Reset
- Select the automatic calibration menu and press
- Fill the tank with clean water and press
AUTO CALIBRAZIONE
- Press
and enter the number of litres in the tank by pressing
reached the required value, press
AUTO CALIBRAZIONE
Premere OK
E aprire il rubinetto
Del serbatoio
- Press
and open the tank emptying tap. Liquid will flow through the flowmeter. DATA-MATE will automatically perform interpolation of the pres-
sure/litre points until the tank has been fully emptied;
- Press
to save tank calibration. Points created are displayed in the CALIBRATION menu by scrolling through the STEP settings of the manual
calibration menu.
200.1012.15
;
;
Riempimento
In CORSO
Premere OK
Per terminare
;
(if you hold the key down, the setting will change rapidly). Once you have
AUTO CALIBRAZIONE
SVUOTAMENTO
IN CORSO
Livello
2000 l
Pressione
150 mBar
13 / 22
AUTO CALIBRAZIONE
Premere OK per
INIZIARE riempimento
Della cisterna
AUTO CALIBRAZIONE
Inserire
Capacità cisterna
Livello
2000 l
AUTO CALIBRAZIONE
Procedura terminata
Premere OK
Per salvare
Rev. 01 01/02/2016