c- Fix the cables to the vehicle chassis
Make sure that the cables are not being pinched or in contact with warm surfaces or sharp edges.
d- Then connect the charger cable.
 After charging, disconnect the battery charger from the mains. Then remove the chassis
connections and the battery connections, in this order. When permanently connected to the
vehicle battery, first disconnect the battery charger from supply mains, then from the battery
connection.
S
UGGESTED MODES AND SELECTION
GYSFLASH has 3 charging modes
ATTENTION: The charging mode can be selected only if the device is connected to the battery.
To select your charging mode, please refer to the following table:
M
ODES
12V
* Remark: to charge sealed batteries used in deep cycle mode , select the « hot » mode.
C
M
HARGING
ODES
The three charging modes follow the diagram below. :
• Diagram showing charging curve
1
Short Circuit test
2
Recovery mode
3
Sulphation test
4
Desulphation
5
Test
6
Charge
EMERGENCY
(i.e. alarm)
LED
Test the cells in the battery for short circuits
Recovers cells damaged deep and prolonged discharge
Tests battery for sulphation
Desulphation and recovery of battery
Check the recovery status of the battery
Charges the battery up to 80%
BATTERY USE
*
DEEP CYCLING
(=charging/discharging ;
i.e.: sweeper...)
4A
0,8A ± 10%
BATTERY VOLTAGE
AUTOMOBILE
&
(including
maintenance
free
batteries)
1.2 to 15 Ah
Normal
GYSFLASH
condition
4A
15 to
Cold
130 Ah
condition
7A
0,8A ± 10%
SIZE
GYSFLASH
7A
15 to
230 Ah
7/33