Allocation of the power assisted filtering devices into device classes
Powered air purifying respirator systems are grouped in device classes according to their respiratory protection capacity.
Table 5
Device class
Powered filtering devices incorporating helmets/hoods, full masks and
particle filters
TH1PR
TH2P R
TH3P R
TM3P R
Powered filtering devices incorporating helmets/hoods, full masks and
gas filters
2)
TH1
TH2
TH3
TM3
This information is correspondingly applicable for combination filters.
The device classes of the compiled combination of components: Filter, powered air supplying unit and head piece, see the corresponding
user manual.
1)
LV (limit values) - MAC = maximum particle concentration in the workplace.
2)
Provided the gas absorption based on the highest permissible gas concentration for gas filters in powered air supplying unit of 0.05%
in vol of gas filter class 1 – 0.1% in vol of gas filter class 2 - and 0.5% in vol of gas filter class 3 will not be exceeded.
Filters used with Honeywell powered air purifying
The Honeywell filters and their classification, for application with Honeywell Powered Air Purifying Respirators, are clearly identified in the
user manual of systems (Compact Air 200 part no. 1793676 and Compact Air part no. 1793677)
After use
-
Store the filters in a cool, dry, location with the caps attached
-
The maximum permissible storage period is specified on the filter
-
Storage temperature range: -20°C / +50°C
-
Maximum humidity during storage: 80%
-
Before disposing of seal off both filter openings
-
When disposing of the filter take in mind that there are hazardous substances present in the filter
GENERAL
Honeywell Respiratory Safety Products cannot, in general terms, accept responsibility for damage incurred by the owner, user, other
persons using the safety product or third parties, which results either directly or indirectly from incorrect use and/or maintenance of the
safety product, including use of the product for any purpose other than that for which it was supplied and/or the non compliance or
incomplete observance of the instructions contained in this user manual and/or in connection with repairs to the safety product which have
not been carried out by us or on our behalf. Our general sales and supply conditions are applicable to all transactions. Honeywell
Respiratory Safety Products strives continuously to improve its products and reserves the right to amend the specifications as given in
this manual without prior notice.
Multiple of the limit
value (LV
1
)
The "open" breathing systems, helmets or hoods, do not
provide sufficient protection when the powered air
supplying unit fails or degrades.
5
Devices without appropriate warning devices and
20
devices of class TH1P may therefore not being used
100
against carcinogenic, very toxic and radioactive
substances, micro-organisms (viruses, bacteria and
500
fungi) and enzymes.
The "open" breathing systems, helmets or hoods, do not
provide sufficient protection when the powered air
5
supplying unit fails or degrades.
Devices without appropriate warning devices and
20
devices of class TH1P may therefore not being used
against carcinogenic, very toxic and radioactive gases
and vapours.
100
On devices with combination filters the respective
restrictions apply for the gas- and particle filters.
500
EN-4