Example Byte Description
DB
-
219 data bytes
01
-
Unit ID
04
-
Function code
D8
-
216 reading bytes
53
High
FD
Low
27
th
AE
High
F0
Low
05
High
0,111 kW phase 1 imported active power AVG (+P1
FC
Low
00
High
0 kW phase 1 exported active power AVG (-P1
00
Low
05
High
0,111 kW phase 2 imported active power AVG (+P2
FB
Low
00
High
0 kW phase 2 exported active power AVG (-P2
00
Low
05
High
0,111 kW phase 3 imported active power AVG (+P3
FA
Low
00
High
0 kW phase 3 exported active power AVG (-P3
00
Low
05
High
0,333 kW system imported active power AVG (+P∑
FB
Low
00
High
0 kW system exported active power AVG (-P∑
00
Low
00
High
0,003 kvar phase 1 imported reactive power AVG (+Q1
2E
Low
00
High
0 kvar phase 1 exported reactive power AVG (-Q1
00
Low
00
High
0,003 kvar phase 2 imported reactive power AVG (+Q2
2D
Low
00
High
0 kvar phase 2 exported reactive power AVG (-Q2
00
Low
00
High
0,003 kvar phase 3 imported reactive power AVG (+Q3
30
Low
00
High
0 kvar phase 3 exported reactive power AVG (-Q3
00
Low
00
High
0,010 kvar system imported reactive power AVG (+Q∑
2F
Low
00
High
0 kvar system exported reactive power AVG (-Q∑
00
Low
53
High
FD
Low
27
th
AF
High
2C
Low
00
High
0 kvar system exported reactive power AVG (-Q∑
00
Low
RECORDING DOWNLOAD FOR ENH INSTRUMENT VERSION
Example with +P∑, +Q∑, +S∑ parameters enabled for recording.
1° STEP: prepare data for downloading
Command example: 01000000000B0110F00000020400000001
01
-
Transaction ID
00
High
00
Low
Protocol ID
00
High
00
Low
100
0B
-
11 data bytes
August 2014, 10:12:00 record block
August 2014, 10:13:00 record block
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
)
AVG
1
RECORD
ST
2
RECORD
ND
6
RECORD
TH
MODBUS RTU/ASCII, TCP