• Technical programming
Now it is adjusted the pre-brewing time for the little pause after the initial
water injection, as to allow the grinded coffee to moisture depending on each
type of selection.
To accept the setting and proceed to the next menu, press the continuous
button.
10.19. Probe sensitivity
Here it can be adjusted the detection sensibility of the level probes of the
boiler. Normally it is not needed to modify it from the "medium", but in some
cases (very pure water, this is water with very low level of dissolved salts), it
will be needed to select High sensibility; and vice versa.
By default this sensibility will be set to "Med", and generally it is not needed
to modify it.
To increase sensibility, press (+)(one short espresso), to decrease it (-)(one large coffee).
To accept the setting and proceed to the next menu, press the continuous button.
10.20. Grinding notice
This setting enables or disables the brewing monitor. This function analyzes
the output flow when brewing, and depending on it, advises if the grinded
coffee is too thin or too coarse. If the brewing flowrate was between limits, it
will display "Ok" at the end of the brewing process.
To enable it, press (+)(one short espresso) to disable it (-)(one large coffee).
To accept the setting and proceed to the next menu, press the continuous button
10.21. Adjusting parameters of the grinding notice:
If in the previous section the grinding notice was enabled, in this menu, its parameters can be adjusted. If it was
disabled, this menu will not appear.
Here it is adjusted the minimum flow rate that will be considered as inferior
limit of a good brewing flowrate. To increase this value, press (+)(one short
espresso), to decrease it (-)(one large coffee).
To accept the setting and proceed to the next menu, press the continuous
button.
Here it is adjusted the maximum flow rate that will be considered as superior
limit of a good brewing flowrate. To increase this value, press (+)(one short
espresso), to decrease it (-)(one large coffee).To accept the setting and
proceed to the next menu, press the continuous button.
10.22. Sequential flashing of lights on touch pads
The blinking of the keypads lights have different behavior modes that can be
toggled by pressing (+)(one short espresso) and (-)(one large coffee). The
options are: Enabled, disabled & Rotation leds.
To accept the setting and proceed to the next menu, press the continuous
button
10.23. Chronometer
The displays of each group have different working modes:
- Brewing chronometer: When brewing an espresso, the display acts as a
chronometer measuring the time taken to erogate the espresso.
- Pulses: The group display, graphically shows the espresso brewing speed
during the espresso erogation by displaying the flowmeter pulses.
- Disabled: Easch group display is not affected when brewing espresso.
To change between the different option use press (+)(one short espresso), or (-)(one large coffee).
To accept the setting and proceed to the next menu, press the continuous button
English
17
Pre-brew. OFF sec
Selection type X.Xs
↑+
-1 espresso
↓ -
-1 large coffee
2 short espressos OK
Continuous to confirm
Probe Sensitivity
Low/Mid/High
↑+
-1 espresso
↓ -
-1 large coffee
2 short espressos OK
Continuous to confirm
Grinding Notice
Enabled/disabled
1 short espresso
+
1 long espresso
-
2 short espressos OK
Continuous to confirm
Thin Grinding
X.X
↑+
-1 espresso
↓ -
-1 large coffee
2 short espressos OK
Continuous to confirm
Thick Grinding
X.X
↑+
-1 espresso
↓ -
-1 large coffee
2 short espressos OK
Continuous to confirm
Led Idle
option
↑+
-1 espresso
↓ -
-1 large coffee
2 short espressos OK
Continuous to confirm
Crono
option
↑+
-1 espresso
↓ -
-1 large coffee
2 short espressos OK
Continuous to confirm