Maintained Contact Switches
Cat. Nos. 1281, 1282, 1285, 1286, 1287, 1288
Cat. Nos. 1081, 1256, 1257, 1260, 1262
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH
APPROPRIATE ELECTRICAL CODES AND REGULATIONS
Interrupteurs à contact maintenu
Nºs de cat. 1281, 1282, 1285, 1286, 1287, 1288
Interrupteurs à contact momentané
Nºs de cat. 1081, 1256, 1257, 1260, 1262
INSTALLER OU UTILISER CONFORMÉMENT AUX
CODES DE L'ÉLECTRICITÉ EN VIGUEUR
Apagadores de Contacto Sostenido
Cat. Nos. 1281, 1282, 1285, 1286, 1287, 1288
Apagadores de Contacto Momentáneo
Cat. Nos. 1081, 1256, 1257, 1260, 1262
PARA INSTALARSE Y/O USARSE
DE ACUERDO CON LOS CODIGOS
ELECTRICOS Y NORMAS APROPIADOS
PK-92648-10-02-0B
LIMITED 10 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of
anyone else that this product at the time of its sale by Leviton is free of defects in
materials and workmanship under normal and proper use for ten years from the
purchase date. Leviton's only obligation is to correct such defects by repair or
replacement, at its option, if within such ten year period the product is returned
prepaid, with proof of purchase date, and a description of the problem to Leviton
Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little
Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and
there is disclaimed liability for labor for removal of this product or reinstallation.
This warranty is void if this product is installed improperly or in an improper
environment, overloaded, misused, opened, abused, or altered in any manner,
or is not used under normal operating conditions or not in accordance with any
labels or instructions. There are no other or implied warranties of any kind,
including merchantability and fitness for a particular purpose, but if any
implied warranty is required by the applicable jurisdiction, the duration of any such
implied warranty, including merchantability and fitness for a particular purpose,
is limited to ten years. Leviton is not liable for incidental, indirect, special,
or consequential damages, including without limitation, damage to, or loss
of use of, any equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are the exclusive
remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
www.leviton.com
PK-92648-10-02-0B
WARNING:
Momentary Switches
WARNING:
WARNING:
MARKED CO/ALR OR CU/AL.
TO INSTALL:
WARNING:
POWER IS OFF BEFORE WIRING!
To Side Wire: Remove insulation from wires to expose 3/4" (1.9 cm) of conductor. Loop wires clockwise 3/4 turn around
terminal screws. Firmly tighten screws over wire loops. Terminal screws accept up to #10 AWG copper or copper clad wire.
To Back Wire: Remove insulation per strip gauge on device [about 1/2" (1.3 cm)]. Insert wires into appropriate wire well and
tighten screw firmly.
Mount device using long mounting screws. Attach wallplate. Restore power at circuit breaker or fuse.
For Single Pole, Double Throw, Center OFF Switches (refer to Figure 1). Ratings for Cat. Nos. (refer to Figure 3).
Connect wires per appropriate WIRING DIAGRAM as follows: BLACK (Hot) wire from power source to the (L1) screw. BLACK
wire from Load #1 to (A1) screw. BLACK wire from Load #2 to (B1) screw. GREEN or BARE (Ground) wire to GREEN screw.
For Double Pole, Double Throw, Center OFF Switches (refer to Figure 2). Ratings for Cat. Nos. (refer to Figure 3).
Connect wires per WIRING DIAGRAM as follows: BLACK (Hot) wire from Line #1 to the BLACK (L1) screw. BLACK (Hot) or
WHITE (Neutral) wire from Line #2 to the BLACK (L2) screw. Load (Hot) wire from the Load #1 to BRASS (A1) screw. Load
(Hot) wire from Load #2 to the BRASS (B1) screw. Connect remaining wires as follows; from Load #1 to BRASS (A2) screw,
from Load #2 to the BRASS (B2) screw and GREEN or BARE (Ground) wire to the GREEN screw.
Figure 1: Single Pole, Double Throw, Center Off
Figure 1 : unipolaire, bidirectionnel, mise hors tension
Figura 1: Unipolar, Bidireccional, Centro APAGADO
Hot (Black)
Actif (Noir)
Fase (Negro)
Green Ground
Terre vert
Verde a tierra
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
Cat. No./N
de cat./No. de Cat. Cat. No./N
o
1081*
1256*, 1281*
1257*, 1285*
1260*, 1287*
* Single Pole Switches/interrupteurs unipolaires/Apagadores Unipolar – ** Double Pole Switches/interrupteurs bipolaires/Apagadores Bipolar
INSTALLATION INSTRUCTIONS
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE
A1
L1
B1
Black/Noir/Negro
Load 2
Charge 2
Carga 2
White/Blanc/Blanco
de cat./No. de Cat.
o
1282**
1286**
1262**, 1288**
Figure 2: Double Pole, Double Throw, Center Off
Figure 2 : bipolaire, bidirectionnel, mise hors tension
Figura 2: Bipolar, Bidireccional, Centro APAGADO
Hot (Black)
Actif (Noir)
Fase (Negro)
L1
Black
Noir
B1
Negro
Load 1
A1
Charge 1
Carga 1
Hot (Black)
Actif (Noir)
White
Fase (Negro)
Blanc
Blanco
Neutral (White)/Neutre (Blanc)/Neutro (Blanco)
Figure 3/Figure 3/Figura 3
Ratings/Valeurs nominales/Capacidad
3A, 24V AC/DC/V c.a./V c.d./V CA/CD
15A-120/277VAC/V c.a./VCA, 1/2HP-120VAC/V c.a./VCA, 2HP-240VAC/V c.a./VCA
20A-120/277VAC/V c.a./VCA, 1HP-120VAC/V c.a./VCA, 2HP-240VAC/V c.a./VCA
30A-120/277VAC/V c.a./VCA, 2HP-120VAC/V c.a./VCA, 2HP-240VAC/V c.a./VCA
Green Ground/Terre vert/Verde a tierra
B2
Black
Noir
Negro
A2
Black/Noir/Negro
Load 1
Load 2
L2
Charge 1
Charge 2
Carga 1
Carga 2
White/Blanc/Blanco
White
Blanc
Blanco

Publicidad

loading

Resumen de contenidos para Leviton 1281

  • Página 1 Figure 1 : unipolaire, bidirectionnel, mise hors tension Figure 2 : bipolaire, bidirectionnel, mise hors tension anyone else that this product at the time of its sale by Leviton is free of defects in Figura 1: Unipolar, Bidireccional, Centro APAGADO...
  • Página 2 PARA EVITAR FUEGO, DESCARGA ELECTRICA, O MUERTE, INTERRUMPA EL PASO DE ENERGIA MEDIANTE EL SOLO PARA MEXICO POLIZA DE GARANTIA: LEVITON S. de R.L. de C. V., LAGO TANA NO. 43 COL. HUICHAPAN, DEL. M. INTERRUPTOR DE CIRCUITO O FUSIBLE. ¡ASEGURESE QUE EL CIRCUITO NO ESTE ENERGIZADO ANTES DE INICIAR LA INSTALACION! HIDALGO MÉXICO D.
  • Página 3 FOLD SCHEME LEVITON INSTRUCTION SHEET/MANUAL SPECIFICATIONS 5.5" PK-92648-10-02-0B Black C a t N o Cat No. 1.83" Helvetica 50 Lb. offset Cat No. 2.83" 8.5" Paper size: 8.5" X 5.5" Overall size: 2.83" X 1.83" Final fold size: FINAL DOCUMENTATION...

Este manual también es adecuado para:

128212851286128712881081 ... Mostrar todo