PERFORMANCE DATA

Pentair FreshPoint Easy Flow
Replacement Filter:
RC-LCT Filter..........Part No: 4005657
Replacement filters may be ordered by visiting
pentair.com/easyflow, which can be reached by
scanning the QR label on the product.
While testing was performed under laboratory conditions, actual
performance may vary.
CLAIM PERFORMANCE CERTIFIED BY NSF*
This system has been tested in accordance to NSF/ANSI 42
and 53 for the reduction of the substances listed below. The
concentration of the indicated substance in water entering the
system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in
NSF/ANSI 42 and 53.
4005653_
FreshPoint Easy
Substance
Flow
Standard 42
Chlorine
2.0 mg/L ± 10%
Taste & Odor
Standard 53
Minimum
Cyst**
50,000 Microsphere/L
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
*Tested using flow rate =2.2 gpm; pressure = 60 ± 3 psig; pH = 7.5 ± 0.5; temp = 20° ± 3°C
** NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by
mechanical means.
EPA Est. No. 090375-MEX-001
Rated Capacity:
Feed Pressure Range:
Temperature Range:
Rated Service Flow:
System Tested and Certified by NSF International
against NSF/ANSI Standards 42 and 53 for
the reduction of the claims specified in the
Performance Data Sheet and at www.nsf.org.
6 •
Pentair FreshPoint Easy Flow User' s Guide
Maximum
Permissible
Reduction
Average
Product Water
Requirements
Reduction
-
≥50%
79.7%
n/a
≥99.95%
>99.99%
0.005 mg/L
n/a
97.7%
0.005 mg/L
n/a
99.5%
3000 gallons (11356 liters)/1-year
40 - 125 psi (2.75 - 8.62 bar)
40 - 100°F (4.4 - 37.8°C)
60 psi: 1.4gpm (5.3 Lpm)