4 .
U sing PVC purple primer and PVC cement (not included),
attach as many couplings and sections of rigid PVC pipe
(not included) to the adaptor as it takes to equal the depth
of the well minus 5 ft.
5 .
B efore sliding the pipe assembly into the well, firmly
clamp the assembly with a pipe clamp (not included) to
prevent the assembly from sliding down into the well.
6 .
R emove pipe clamp and slide well seal (not included)
over the PVC pipes and onto the well casing. The PVC
pipe should extend approximately 12 in. from the well
seal, depending on the height of the pump (A).
N OTE: DO NOT let assembly slide down into well.
Tighten the well seal until rubber gaskets are tight
against the well casing and the PVC pipes.
7 .
C ut the 1 in. pipe 2 in. shorter than the 1-1/4 in. pipe.
Smooth rough edges. Using PVC purple primer and PVC
cement (not included), attach a 1 in. PVC elbow and a
1-1/4 in. PVC elbow (both facing the pump) to the pipes
extending from the well seal.
8 . W rap thread tape around the threads of a 1-1/4 in. male
PVC adaptor (not included). Thread the adaptor into the
top hole in the front of the pump (A).
W rap thread tape around the threads of a 1 x 5 in. nipple
(not included). Thread the nipple into the bottom hole in
front of the pump (A).
W rap thread tape around the threads of a 1 in. female
PVC adaptor (not included). Thread the adaptor onto the
1 x 5 in. nipple.
4
5
6
7
8
A