USER'S MANUAL. REMOTE CONTROL COMMANDS SATHUNTER
*RST
Reboots the equipment.
COMMAND:
*PWR
Provides the power rate measurement and the maximum power rate
COMMAND:
RESPONSE:
*POW
Provides the measurement of the power rate with the measure units selected on the
current test point configuration. With the SPC order, conversion of units may be
cancelled and the POW order will always return dBµV.
COMMAND:
RESPONSE:
*MER
Provides MER measurement of the current test point.
COMMAND:
RESPONSE:
06/2008
*RST<CR>
*?PWR<CR>
*PWRxxyy<CR>
where xx is the current power rate (in hexadecimal notation) 00
minimum <-> 100 maximum.
where yy is the maximum power rate (in hexadecimal notation)
00 minimum <-> 100 maximum.
*?POW<CR>
*POWyxxxx<CR>
where y indicates whether the measurement floods above or
below the allowed margin.
"<" the measurement is smaller than the minimum measurable.
">" the measurement is larger than the maximum measurable.
" " the measurement is within the measurement margin.
where xxxx is the power measured in tenths of dBµV
*?MER <CR>
*MERyxxxx<CR>
where y indicates whether the measurement floods above or
below the allowed margin.
"<" the measurement is smaller than the minimum measurable.
">" the measurement is larger than the maximum measurable.
" " the measurement is within the measurement margin.
where xxxx is MER measured in tenths of dB.
Page 7