Multi-Stage
Canister Filters
Never use soap, abrasives or any other
cleaning agent on or around filter or aquarium.
Never attempt to open Motor Head when filter is in use.
Never submerge Motor Assembly.
For Optimum Performance
Clean Filter
Media regularly
Rinse with water from
aquarium. NOT
TAP WATER.
Rinse Filter Foam
every three weeks
and replace after
nine weeks.
IMPORTANT SAFEGUARDS
WARNING: To guard against injury, basic safety precautions should be observed, including the following.
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
DANGER: To avoid possible electric shock, special care should be taken in the use of aquarium equipment.
For each of the following situations, do not attempt repairs yourself. Return the appliance to an authorized
service facility for service or discard the appliance.
1. A. If the appliance falls into the water, DON'T reach for it. First unplug it and then retrieve it.
If electrical components of the appliance get wet, unplug the appliance immediately.
B. If the appliance shows any sign of abnormal water leakage, immediately unplug from the power source.
C. Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not
intended to be wet.
D. Do not operate any appliance if it has a damaged cord or plug, or if it
is malfunctioning or if it is dropped or damaged in any manner.
E. To avoid the possibility of the appliance plug or receptacle getting wet,
position aquarium stand and tank to one side of a wall mounted receptacle
to prevent water from dripping onto the receptacle or plug. A "drip loop,"
shown in the figure at right, should be arranged by the user for each cord
connecting an aquarium appliance to a receptacle. The"drip loop" is that
part of the cord below the level of the receptacle or the connector, if an
extension cord is used, to prevent water from traveling along the cord
and coming in contact with the receptacle. If the plug or receptacle does
get wet, DON'T unplug the cord. Disconnect the fuse or circuit breaker that
supplies power to the appliance. Then unplug and examine for presence
of water in the receptacle.
2. Close supervision is necessary when any appliance is
used by or near children.
3. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, etc.
4. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before
cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
5. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the
appliance manufacturer may cause an unsafe condition.
6. Do not install or store the appliance where it will be exposed to the weather or to temperatures
below freezing.
7. Make sure an appliance mounted on a tank is securely installed before operating it.
8. Read and observe all the important notices on the appliance.
9. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes
or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not
be tripped over or pulled.
10. This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in
a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not
attempt to defeat this safety feature.
SAVE THESE INSTRUCTIONS
M
:
ODELS
C-160, C-220
C-360
AND
IMPORTANT:
Clean Impeller
Assembly Cover and
Impeller monthly.
Rinse thoroughly under
warm tap water.
Replace Filter
Floss Pad and
Carbon Filter Bags
every month.
AQUARIUM
APPLIANCE
POWER CORDS
DRIP LOOP
Troubleshooting Guidelines
SYMPTOM
•
Restart Filter.
IF Filter makes excessive
Make sure top of Motor Head is located at least 20 inches below aquarium water level.
•
noise during operation...
See that O-Rings are not dirty, damaged or worn. Replace, lubricate and/or realign
•
as necessary.
Check Impeller for wobbling or wear. If evident, clean or replace immediately.
•
•
Rinse Impeller Case and Impeller to clear dirt or obstructions.
Remove any remaining air in the filter by pulling and replacing plug 3-4 times in
•
succession. Gently shake filter.
Isolate leak and check all fittings.
•
IF leakage occurs...
Make sure all Motor Head Buckles are closed/secured.
•
•
Inspect edge of Motor Head for scratches, gouges or other damage.
Replace Motor Head if damaged.
Check to see that Filter Case and O-Ring are free of dirt and/or debris.
•
Make sure Valve Block is assembled properly.
•
•
Make sure O-Rings are properly positioned. If damaged, replace immediately.
Make sure that Intake Strainer is located away from air stones or bubbling
•
ornaments.
IF air buildup occurs...
Check hoses for proper connection.
•
Make sure Intake Tube-to-Intake Strainer connection is BELOW water surface.
•
LIMITED WARRANTY
Within three years from the date of original purchase,
Marineland Aquarium Products will repair or replace, at its option, any C-160, C-220
C-360 Canister Filter which is deemed defective in workmanship or materials. Please
return the unit, together with proof of date of purchase:
Call (800) 322-1266 for return authorization and shipping address.
Damage or injuries resulting from negligence or misuse are not covered by this
warranty. Incidental or consequential damages are specifically excluded*. This
warranty gives you specific legal rights. You may also have other rights which
vary from state to state.
*Because some states do not allow the exclusion of incidental or consequential damages, this exclusion may not apply to you.
(800) 322-1266 www.marineland.com
Parts Diagram & Identification
1
3
4
5
Replacement Parts List
KEY
ITEM DESCRIPTION
1
Valve Block
2
Impeller Assembly
3
Filter Media Securing Plate
4
Stack n' Flo Filter Trays
5
Stack n' Flo Filter Tray with
Directional Flow Dish
6
Intake Tube & Strainer
7
Outlet Tube, Diffuser & Elbow
8
Vinyl Tubing
9
Suction Cups
10
Clamps
Questions or Missing Parts: Call Customer Service
(800) 322-1266
COMMENTS/SOLUTION
IMPORTANT:
Always unplug system
before inspecting
or disassembling for
any reason.
09/07 P/N AQ11988
2
7
6
10
8
C-160
C-220
AQ11717
AQ11717
PRIM160
PRIM220
AQ11718
AQ11718
AQ11719
AQ11719
AQ11720
AQ11720
AQ11721
AQ11721
AQ11722
AQ11722
PA11487
PA11487
AQ11723
AQ11723
AQ11724
AQ11724
9
C-360
AQ11756
PRIM360
AQ11757
AQ11758
AQ11759
AQ11760
AQ11761
PA11488
AQ11762
AQ11763