H.O.T. MAGNUM &
H.O.T. MAGNUM BIO-PRO SYSTEM
C
ONVERTIBLE
Model# H.O.T. Magnum 250HSB
For Optimum Performance
H.O.T. MAGNUM
• Never wash with soap or cleaning agents.
• Replace Filter Media every 2-4 weeks.
Black Diamond Premium Activated Carbon
is available at your local Marineland dealer.
• Clean Canister thoroughly (Rinse only).
• Clean Impeller monthly (gently squeeze sides to
pop open). Check for wear and smooth rotation.
• Clean Intake Tube monthly.
• Clean Micron Cartridge Regularly (Rinse only).
• Clean Air Ejector Tube with the Nylon Cleaning
Wand Regularly.
• Gently clean flat Exhaust Gaskets (warm
water only).
• Wash D-Ring Seating Area on Canister and Cover.
Wet D-Ring and reinstall.
IMPORTANT SAFEGUARDS
WARNING: To guard against injury, basic safety precautions should be observed, including the following.
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
DANGER: To avoid possible electric shock, special care should be taken in the use of aquarium equipment.
For each of the following situations, do not attempt repairs yourself. Return the appliance to an authorized
service facility for service or discard the appliance.
1. A. If the appliance falls into the water, DON'T reach for it. First unplug it and then retrieve it.
If electrical components of the appliance get wet, unplug the appliance immediately.
B. If the appliance shows any sign of abnormal water leakage, immediately unplug from the power source.
C. Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not
intended to be wet.
D. Do not operate any appliance if it has a damaged cord or plug, or if it
is malfunctioning or if it is dropped or damaged in any manner.
E. To avoid the possibility of the appliance plug or receptacle getting wet,
position aquarium stand and tank to one side of a wall mounted receptacle
to prevent water from dripping onto the receptacle or plug. A "drip loop,"
shown in the figure at right, should be arranged by the user for each cord
connecting an aquarium appliance to a receptacle. The"drip loop" is that
part of the cord below the level of the receptacle or the connector, if an
extension cord is used, to prevent water from traveling along the cord
and coming in contact with the receptacle. If the plug or receptacle does
get wet, DON'T unplug the cord. Disconnect the fuse or circuit breaker that
supplies power to the appliance. Then unplug and examine for presence
of water in the receptacle.
2. Close supervision is necessary when any appliance is
used by or near children.
3. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, etc.
4. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before
cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
5. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the
appliance manufacturer may cause an unsafe condition.
6. Do not install or store the appliance where it will be exposed to the weather or to temperatures
below freezing.
7. Make sure an appliance mounted on a tank is securely installed before operating it.
8. Read and observe all the important notices on the appliance.
9. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes
or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not
be tripped over or pulled.
10. This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in
a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not
attempt to defeat this safety feature.
SAVE THESE INSTRUCTIONS
C
F
ANISTER
ILTERS
BIO-WHEEL PRO
• Once every month, gently brush the BIO-Wheel's
housing and cover to remove any mineral or
salt crust.
• Once every month, clean the spray bar with rigid
brush. To do so, shut off the water supply, release
the clips and remove the spray bar.
• Every three months, disconnect fittings and
clean inside hose with Brush. Inspect O-rings
for damage and replace if necessary.
• A properly cultured BIO-Wheel is brown or
discolored, and may rotate irregularly. This is
normal. If it becomes so heavily cultured that it
no longer rotates, gently rinse its surface to
remove the heaviest buildup. Use only room-
temperature dechlorinated water.
APPLIANCE
AQUARIUM
POWER CORD
DRIP
LOOP
Troubleshooting Guidelines
IF pumping will not start or flow is diminished.
Clean or replace Filter Sleeve, Carbon/Media
Container, or Micron Cartridge. Also check that
Impeller Module and Impeller are clean, properly
installed and free to rotate. See that Exhaust Gaskets
are in proper position.
IF filter makes excessive noise or stops
abruptly. Be sure Impeller and Impeller Module are
properly installed. Also check Impeller Magnet for
wobbling or wear. If evident, replace immediately.
Check Sleeve, Carbon/Media Container, or Micron
Cartridge for clogging - clean or replace. Rinse Canister.
Always use Black Diamond Premium activated
Carbon to avoid small particles getting into impeller
mechanism.
IF air accumulates in Canister during operation.
Inspect Air Ejector Tube. If clogged, use Nylon Cleaning
Wand to dislodge dirt. Move Intake away from air-
stone bubbles or other air source. Also check hose
connections ensure that air is not being sucked in.
Make sure O-Rings and D-Ring are not dirty, dam-
aged or worn. Replace and/or realign as necessary.
IF leakage occurs at hose connections.
Position hose and/or Hose Retainer Bands properly.
Or reinstall with light coating of silicon lubricant.
LIMITED WARRANTY
Within three years from the date of original purchase, Marineland Aquarium Products will repair or replace,
at its option, any H.O.T. MAGNUM 250 or H.O.T. MAGNUM 250 BIO-PRO Canister Filter which is deemed
defective in workmanship or materials. Please return the unit, together with proof of date of purchase:
Call (800) 322-1266 for return authorization and shipping address.
Damage or injuries resulting from negligence or misuse are not covered by this warranty. Incidental
or consequential damages are specifically excluded*. This warranty gives you specific legal rights.
You may also have other rights which vary from state to state.
*Because some states do not allow the exclusion of incidental or consequential damages, this exclusion may not apply to you.
(800) 322-1266 www.marineland.com
Parts Diagram & Identification
NOTE: Black Diamond Premium activated Carbon and
16
Rite Size "U" Filter Sleeve are not considered replacement parts.
1
3
They may be purchased at your local Marineland dealer.
16
4
17
5
2
6
13
7
14
5
15
8
11
9
10
12
Replacement Parts List
KEY
ITEM DESCRIPTION
ITEM NO.
1
Intake & Outlet Tube Set w/Diffuser PR1500
2
Intake Strainer
PR1505
3
Cover
PR1512
4
D-Ring Cover Seal
PR1513
5
Exhaust Gasket - Pkg. 2
PR1514
6
Internal Flow Diffuser
PR1515
7
Center Exhaust Tube
PR1530
8
Impeller Module (3 parts)
PR1568
9
Magnetic Impeller Assembly (blue) PR1581
10
Motor & Canister Assembly
PR1536
11
Canister Collar
PR1538
12
Leveling Clip
PR1585
13
Carbon Media Container
PR1545
14
Micron Cartridge
PA0140
Questions or Missing Parts: Call Customer Service
(M-F 8am to 5pm, Eastern Time)
IF leakage occurs along rim of Canister Cover.
Check to see that O-Ring is positioned properly. If
O-Ring is damaged, replace immediately. Wash
O-Ring seal area thoroughly. If leak persists, try
lubricating O-Ring lightly with silicon lubricant.
IF Intake Tube is too long.
Cut to desired length and reinstall.
IF Intake Tube is too short.
3
Purchase
/
" diameter extension from aquarium
4
dealer (PA1341).
BIO-WHEEL PRO
If water does not flow from the BIO-Wheels.
Inspect the Spray Bars for obstruction or buildup.
Also, make sure that the Magnum is plugged in and
that its valves are open. Lastly, check its impeller
system for grit or debris.
If water flow is reduced or the BIO-Wheel
will not rotate. Check the Magnum media for
heavy clogging. If the media is clogged, change it
or clean it. If it's not clogged, try cleaning and/or
readjusting the Spray Bar. Also try cleaning or
replacing the BIO-Wheel's bearings.
IMPORTANT:
Always unplug Canister
Filter before inspecting
or disassembling for
any reason.
05/07 P/N 11956
BIO-Wheel PRO
18
19
20
24
21
23
22
KEY
ITEM DESCRIPTION
15
Micron Cartridge Core
16
O-Ring-Intake/Outlet - Pkg. 4
17
Connector Clips - Pkg. 2
BIO-Wheel PRO Replacement Parts List
18
Outlet Adapter - Pro Version Only PR1516
19
Spray Bar O-Rings Pkg. 4
20
Spray Bar Assembly
21
BIO-Wheel Assembly
22
Bearing - Pkg. 2
23
Nut & Screw - Pkg. 2 (L-R Set) PA2007
24
Connector Clips - Pkg. 2
25
Barbed Elbow Adapter
26
Barbed Elbow Connector
(800) 322-1266
26
25
24
ITEM NO.
PR1420
PR1550
PR1503
PR2045
PR2006
PR2002
PR2001
PR2004
PA2030
PR2035