3.1.4

Motor overload protection

DRC.. is provided with load and speed-sensitive overload protection and thermal me-
mory retention upon shutdown or power loss.
The trip current is adjusted to 150% of the rated motor current.
3.1.5

Ambient temperature

DRC.. is suitable for an ambient temperature of 40 °C, max. 60 °C with derated output
current. To determine the output current rating at temperatures above 40 °C, the out-
put current should be derated by 3.0% per K between 40 °C and 60 °C.
3.1.6

Wiring diagrams

For wiring diagrams, refer to chapter "Electrical installation".
Corrección – DRC..-DBC, DRC..-DAC, DRC..-DSC, DRC..-SNI
Normas de instalación
UL-compliant installation