Order number 38.5230
5 Operation with DMX Controller
To control the LEDs connected via a light con-
troller with DMX512 protocol, the CU-4DMX is
equipped with four DMX control channels:
Channel
DMX Value
Function
0 → 255
dark → bright
red
1
0 → 255
green dark → bright
2
0 → 255
blue dark → bright
3
0 → 255
white dark → bright
4

5.1 DMX connection

For the DMX connection, RJ45 jacks with the fol-
lowing pin configuration are available:
Pins 1, 2
Pins 3, 5, 7
ground
DMX -
For connection to DMX units with 3-pole XLR
jacks / plugs use the matching XLR adapter cable
supplied (XLR pin configuration: 1 = ground,
2 = DMX-, 3 = DMX+). Several CU-4DMX can be
connected with each other by interconnecting
their adapter cables.
When using longer cables, special cables for high
data flow should be used. Standard microphone
cables with screening and a minimum cross sec-
tion of 2 × 0,22 mm
2
and with a capacity as low as
possible can only be recommended for a total
cable length of up to 100 m. For cable lengths
exceeding 150 m it is recommended to insert a
DMX level matching amplifier (e. g. SR-103DMX
from "img Stage Line").
Button
R
red
red + white
(= red)
constant
constant
G
green
green + white
(= green)
constant
constant
Y
yellow
yellow + white
(= yellow)
constant
constant
B
blue
blue + white
(= blue)
constant
constant
P
purple
purple + white
(= purple)
constant
constant
C
cyan
cyan + white
(= cyan)
constant
constant
white
RGB + white
RGB
constant
constant
Control programmes
1) Connect the DMX input (2) to the DMX output
of the light controller.
2) Connect the DMX output (1) to the DMX input
of the next CU-4DMX or the next DMX-con-
trolled unit. Connect its output again to the
input of the following unit etc., until all DMX
units are connected in a chain.
3) To prevent interference when transmitting sig-
nals, for long cables or for a great number of
units connected in series, the DMX output of
the last DMX unit of the chain should be termi-
nated with a 120 Ω resistor (> 0.3 W): Insert a
corresponding terminating plug (e. g. DLT-123
from "img Stage Line") into the XLR jack of the
last unit (or into the XLR inline jack of the
adapter cable for a CU-4DMX as the last unit).
Pins 4, 6, 8

5.2 Adjusting the start address

DMX +
For operating the CU-4DMX with a light controller,
adjust the DMX start address for its first DMX
channel. The following DMX channels are then
automatically assigned to the following addresses.
Example: For start address 5 for the first chan-
nel, the channels 2 to 4 are assigned to the
addresses 6 to 8. The address 9 is the next
possible free start address for the following
DMX-controlled unit.
The start address is adjusted as a binary number
via the DIP switch block (7). A place value is
assigned to each of the switches according to the
binary code. By addition of the place values of
the switches set to the upper position the start
address will result.
Press the button repeatedly to switch over between the programmes of a line.
red – white
gradual change
green – white
gradual change
yellow – white
gradual change
blue – white
gradual change
purple – white
gradual change
cyan – white
gradual change
white
gradual transition
dark ↔ bright
®
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
©
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
red
red – white
gradual transition
fast change
dark ↔ bright
green
green – white
gradual transition
fast change
dark ↔ bright
yellow
yellow – white
gradual transition
fast change
dark ↔ bright
blue
blue – white
gradual transition
fast change
dark ↔ bright
purple
purple – white
gradual transition
fast change
dark ↔ bright
cyan
cyan – white
gradual transition
fast change
dark ↔ bright
gradual change
gradual change
red – white
red
green – white
yellow
blue – white
green
yellow – white
cyan
purple – white
blue
cyan – white
purple
white
The following three examples show the switches
in black.
1)
place value
switch number

address 1 (place value 1):
switch No. 1 in the upper position
2)
address 5 (place value 4 + 1):
switches No. 3 and No. 1 in the upper position
3)
address 104 (place value 64 + 32 + 8):
switches No. 7, No. 6 and No. 4 in the upper position
After adjusting the start address, switch on the
power supply for the CU-4DMX. The LEDs con-
nected can now be operated via the light controller.
6 Specifications
Total current rating: . . 10 A max.
Power supply: . . . . . . 12 – 24 V , depending on
the connected LEDs
No-load current: . . . . approx. 35 mA
Ambient temperature: 0 – 40 °C
Dimensions: . . . . . . . 125 × 30 × 45 mm
Weight: . . . . . . . . . . . 268 g
Subject to technical modification.
red + white
red
gradual transition
flashing
dark ↔ bright
green + white
green
gradual transition
flashing
dark ↔ bright
yellow
red – green
flashing
gradual change
blue + white
blue
gradual transition
flashing
dark ↔ bright
purple
red – blue
flashing
gradual change
cyan
green – blue
flashing
gradual change
fast change
fast change
red
green
yellow
blue
purple
cyan
white
A-1192.99.02.05.2011
red
green
blue

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

38.5230

Tabla de contenido