Incandescent Dual Dimmer
S2-L, S2W-L
Rated at 120VAC, 60Hz, 300W maximum each slider.
Purchase wallplate separately.
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting
fixtures,or transformer-supplied appliances.
2. Dimmer requires separate wires in the wallbox for each light circuit.
3. Do not use for lights switched from two locations (3-Way).
4. Use only with permanently installed incandescent fixtures.
5. Dimmer may feel warm to the touch during normal operation.
6. For new installations, wire a test switch before installing the control.
7. Install in accordance with all national and local electrical codes.
8. Clean dimmer with a soft damp cloth only . Do not use any
chemical cleaners.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections before wiring (see
below). Use pliers to bend each side section up and down until it breaks off. Repeat for
each side section to be removed. Reduction of dimmer capacity is also required. Refer
to chart below for maximum capacity.
Remove all inner
side sections
(shaded).
Do not remove
outer side
sections.
Model
No Sides
1 Side
Number
Load
Removed
Removed
S2-L
Incandescent
300W/300W
250W/250W
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center . Please provide exact model number when calling.
(800) 523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call (610) 282-3800
Fax (610) 282-3090
Internet: www.lutron.com
Limited Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after
purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg,
PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER
THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE,
ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER
INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES
ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR
USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some
states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an
implied warranty may last, so the above limitations may not apply to you.
This product may be covered by Mexican patent 168,884 and one or more of the following U.S. patents:
4,833,277; 4,835,816 and corresponding foreign patents. Lutron and Skylark are registered trademarks of
Lutron Electronics Co., Inc.
© 2001 Lutron Electronics Co., Inc.
Installation
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
Separate wires are required in the wallbox for each light circuit.
Step 1
Turn power OFF at circuit breaker or remove fuse.
For new construction go to Step 5.
Step 2
Remove wallplate. Pull switch from wall.
Step 3
Verify application. This dimmer mounts in a single-gang
wallbox and controls two independent lights, 300 Watt
maximum for each slider. Independent wire must be
provided for each light.
Tag the wire that is connected to the
feed side of the switch (the side with
the break-off fin).
Break-off
fin
2 Sides
Removed
Tag
200W/200W
Step 4
Disconnect switch wires.
Turn screws to loosen.
Step 5
Prepare wires. Twist and trim wires to the proper length
indicated below when completing Step 6.
Strip length: 3/8" for 14, 16, or 18 gauge.
3/8"
Note: Wire connectors provided are
suitable for copper wire only. For
aluminum wire, consult an electrician.
Use to join the following combinations:
One 14 gauge wire with one 16 or 18
gauge.
Español en el reverso
Step 6
Wire the control:
Tag
Yellow
Red
Black
Green
Ground
Hot
Yellow
Black
120V
Red
Green
60Hz
Ground
Light
Step 7
Mount and align dimmer. Install wallplate.
Start screws.
Step 8
Turn power ON.
Operation
LIGHT
Bright
Dim
Off
Twist wire
connector tight.
Be sure no
bare wire
is exposed.
S2-L, S2W-L
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 8/01 P/N 030-487 Rev. B
• Connect the green ground wire
on the dimmer to the green or
bare copper ground wire in the
wallbox. If there is no ground
wire in your wallbox, consult an
electrician.
• Connect the black wire on the
dimmer to the tagged wallbox
wire removed from the switch
(feed wire from breaker panel).
• Connect the red wire on the
dimmer to the wallbox wire
leading to one of the lights.
• Connect the yellow wire on the
dimmer to the wallbox wire
leading to the other light.
Light
Neutral
Align control and
tighten screws.
LIGHT
Bright
Dim
Off

Publicidad

loading

Resumen de contenidos para Lutron Skylark S2-L

  • Página 1 Bright Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, Step 5 Prepare wires.
  • Página 2 (Valido solamente en Estados Unidos, Canada, Puerto Rico, y el Caribe.) Prepare los alambres. Corte o pele los alambres a la Lutron reparará o reemplazará, a su criterio, cualquier unidad cuyos materiales o fabricación resulten defectuosos en el término de un año medida correcta para completar Paso 6.

Este manual también es adecuado para:

Skylark s2w-l