Extension Cords; Voltage And Circuit Protection - Craftsman 919.167321 Instrucciones De Seguridad E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Extension Cords

Using extension cords is not recom-
mended. The use of extension cords
will cause voltage to drop resulting in
power loss to the motor and overheat-
ing.
Instead of using an extension cord,
increase the working reach of the
air hose by attaching another length
of hose to its end. Attach additional
lengths of hose as needed.
If an extension cord must be used, be
sure it is:
a 3-wire extension cord that has a
3-blade grounding plug, and a 3-
slot receptacle that will accept the
plug on the product
in good condition
no longer than 50 feet
14 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 12 AWG and 10 AWG
may also be used. DO NOT USE
16 OR 18 AWG.)

Voltage and Circuit Protection

Refer to the specification chart for the
voltage and minimum branch circuit
requirements.
compressors can be operated on
a 15 amp circuit if the following
conditions are met.
1.
Voltage supply to circuit must
comply with the National
Electrical Code.
2.
Circuit is not used to supply any
other electrical needs.
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a 15 amp
circuit breaker or 15 amp time
delay fuse. NOTE: If compressor
is connected to a circuit protected
by fuses, use only time delay
fuses. Time delay fuses should be
marked "D" in Canada and "T" in
the US.
If any of the above conditions cannot
be met, or if operation of the compres-
sor repeatedly causes interruption
of the power, it may be necessary to
operate it from a 20 amp circuit. It is
not necessary to change the cord set.
11 - ENG
Risk of Opertion.
Certain air
A17883

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido