INSTALLATION
INSTALL SUCTION WEIGHT TO SUCTION LINE
1. Drill a hole into the bung cap or solution tank lid. Slide the tubing through and secure
the weighted strainer to the line.
2. To attach the strainer, slide approximately 3.5" of tubing through the collet and lock
into place on strainer body. Pull tubing to make sure it is secure.
3. Suspend slightly above tank bottom to reduce the chance of sediment pickup.
DO NOT mix chemicals in the solution container. Follow recommended mixing
procedures according to the manufacturer.
DO NOT operate pump unless chemical is completely in solution. Turn pump off
when replenishing solution.
DO NOT slide tubing all the way to the bottom of the weighted strainer. Tubing
could become flush with the nose of the strainer and the pump may not prime
due to blockage.
3.5"
(9 cm)
continued
Suction Line
Weighted
Suction Line
Strainer