TROUBLESHOOTING

Trouble
Digital display not
illuminated.
Fan not operating
(digital display is
illuminated).
Fan running
continuously.
Poor evaporation of
water.
Neither bottle
emptying.
Bottles continue to
empty after complete
filling.
Left bottle not
emptying.
Bottle empties
completely
Refill display "F" is on
before bottles are
empty.
Water leaking from
unit
Probable Cause
• No Power.
• Power button has not
been depressed.
• Nighttime button has
been depressed
• ROOM humidity level is
not 3% or more below
SET humidity level.
• Bottles are empty.
• Float is obstructed.
• SET humidity level is
65%.
• ROOM humidity level
has not reached 1% or
more above SET
humidity level.
• CHECK FILTER (CF)
message flashing.
• Mineral buildup on filter
(wick).
• Unit is not level
• Bottle cap plunger
missing post in bottom of
cabinet
• Dirty wicks.
• Air is entering water
bottle.
• Right bottle contains
water.
• This is normal for initial
filling
• Unit is not set up on a
level surface. (Float
will not sense water at
the front of the
cabinet.)
• Bottle caps not properly
tightened or situated
9
Remedy
• Check 120 volt power source.
• Press power button once to
turn on.
• Press any button on the control and
the control panel will illuminate.
• Raise SET humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
• Free float from obstruction
• A SET humidity percentage of 65%
operates fan continuously. Adjust
SET level between 25% - 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to a fresh new wick
NOTE: Local water varies from area
to area and under certain conditions
minerals will build up more rapidly in
the wick.
• Unplug unit for 1-2 minutes to reset
CF function
• Ensure unit is placed on level area
• Check orientation of bottles.
Reposition so that bottle cap
plunger (stem) is depressed by
post in bottom of cabinet.
• Change to fresh new wick
• Check valve assembly caps to
ensure tightness.
• Check for leak in water bottle.
•The humidifier is designed so that
right bottle empties first.
• Ensure unit is level
• Refill bottle for maximum
run time.
• Position unit level. (Some carpet
padding may allow unit to sit lower
in the front than rear with the
additional weight of water bottles in
the front of the cabinet.).
• Check that fill cap is secure and
bottle cap is correctly aligned in
base.
.