SUMMER STORAGE
1. Clean unit as outlined in Care & Maintenance section.
2. Discard used wick and any water in the reservoir or bottles and allow to dry
thoroughly before storage. Do not store with water inside reservoir or bottles.
3. Do not store unit in an attic or other high-temperature area, as damage will occur.
4. Install new filter at beginning of season.

TROUBLESHOOTING

Trouble
Digital display not
illuminated.
Fan not operating
(digital display is
illuminated).
Fan running
continuously.
Poor evaporation of
water.
Neither bottle
emptying.
Bottles continue to
empty after complete
filling.
Left bottle not
emptying.
Bottle empties
completely
Refill display "F" is on
before bottles are
empty.
Probable Cause
• No Power.
• Power button has not
been depressed.
• ROOM humidity level is
not 3% or more below
SET humidity level.
• Bottles are empty.
• Float is obstructed.
• SET humidity level is
65%.
• ROOM humidity level
has not reached 1% or
more above SET
humidity level.
• CHECK FILTER (CF)
message flashing.
• Mineral buildup on filter
(wick).
• Unit is not level
• Bottle cap plunger
missing post in bottom of
cabinet
• Dirty wicks.
• Air is entering water
bottle.
• Right bottle contains
water.
• This is normal for initial
filling
• Unit is not set up on a
level surface. (Float
will not sense water at
the front of the cabinet.)
• Float not activating
switch on chassis.
• Check 120 volt power source.
• Press power button once to
turn on.
• Raise SET humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
• Free float from obstruction
• A SET humidity percentage of 65%
operates fan continuously. Adjust
SET level between 25% - 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to a fresh new wick
NOTE: Local water varies from area
to area and under certain conditions
minerals will build up more rapidly in
the wick.
• Unplug unit for 1-2 minutes to reset
CF function
• Ensure unit is placed on level area
• Check orientation of bottles.
Reposition so that bottle cap
plunger (stem) is depressed by
post in bottom of cabinet.
• Change to fresh new wick
• Check valve assembly caps to
ensure tightness.
• Check for leak in water bottle.
•The humidifier is designed so that
right bottle empties first.
• Ensure unit is level
• Refill bottle for maximum
run time. DO NOT OVERFILL.
• Verify unit is level.
• Reposition chassis so that float
and switch are aligned.
• Verify float is not damaged.
9