CARE & CLEANING
Switch off the power supply
before cleaning
AIR FILTER
Vacuum, wash and dry.
Remove
SUPERSONIC AIR
PURIFYING DEVICE
Vacuum the super
alleru-buster filter.
Vacuum, wash and
dry the frame.
Hints
Clean the filter regularly as dirty filters will cause unpurified air, low cooling or heating capacity, unpleasant smells and higher energy
●
consumption.
The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an authorized
●
dealer to perform seasonal inspections in addition to regular cleaning.
This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being
●
damaged by abnormally strong lightning activity, you may switch off the power supply.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions:
• Abnormal noise during operation
• Water/foreign particles have entered the Remote Control
• Water leak from Indoor unit
FRONT PANEL
Raise and pull to remove.
Wash and dry.
Remove
Remove
INDOOR
UNIT
Wipe gently.
IONIZER
Clean with cotton
bud.
• Circuit breaker switches off frequently
• Power cord becomes unnaturally warm
• «TIMER» flashes
• Switches or buttons are not functioning properly
■ Washing Instructions
• Do not use benzene, thinner or
scouring powder.
• Use soaps or neutral household
≃
detergent (
pH7) only.
• Do not use water with temperature
higher than 40°C.
INDOOR UNIT
• Wipe the unit gently with a soft, dry
cloth.
AIR FILTER
• It is recommended to clean the air
filters once every 2 weeks.
• Purchase the replacement filter if it
is damaged.
Part no.: CWD001137 (Left)
CWD001138 (Right)
SUPER ALLERU-BUSTER
• It is recommended to clean the filter
every 6 months.
• Replace the filter every 3 years or
purchase the replacement filter if it
is damaged.
Part no.: CZ-SA13P
IONIZER
• It is recommended to clean the
ionizer every 6 months.
■ Preparation for extended
Non-operation
• Operate the unit for 2~3 hours using
ion operation to dry the internal parts.
• Turn off the power supply.
• Remove the remote control batteries.
■ Pre-season Inspection
• This inspection is recommended
before operating the air conditioner
at every season.
• Check if the remote control batteries
needed to be replaced.
• Ensure there is no obstruction at all
air intake and outlet vents.
• After the start of operation for 15
minutes, it is normal if the
temperature differences between
air intake and outlet vents at indoor
unit is:-
Operation
Temperature
Cooling
8°C
Heating
14°C
7