Technical specifications
1200 Series Entrance Panels:
• Cover plate made of AISI 316 stainless steel (4VA) 8/10
thick, with embossed surface (stainless steel) or with PVD
treatment (gold effect)
• Can be wall-mounted or flush-mounted with relevant ac-
cessories
• IK10-rated for protection against impact (except for Audio/
Video cover plates for alphanumeric electronic units and
related additional plates with name cards for alphanumer-
ic electronic units).
• Protection class: IP44
• Die-cast aluminium heads (that enable fixing the front plate
to the frame with a special ELVOX screw)
• Support for transparent shockproof polycarbonate buttons
• Stainless steel frame.
• Transparent polycarbonate buttons covered with stainless
steel protection
Reinforced 1200 Series Entrance Panels:
• Cover plate made of AISI 316 stainless steel (4VA) 8/10
thick, with weatherproof satin finish (sable grey) paint
treatment also for installation in saline environments.
• Can be flush-mounted with relevant accessories
• IK10-rated for protection against impact (except for Audio/
Video cover plates for alphanumeric electronic units and
related additional plates with name cards for alphanumer-
ic electronic units).
• Protection class: IP44
• Die-cast aluminium heads (that enable fixing the front plate
to the frame with a special ELVOX screw)
• Support for transparent shockproof polycarbonate buttons
• Stainless steel frame.
• Transparent polycarbonate buttons covered with stainless
steel protection
The items in the 1200 series enable making entrance
panels for audio and video door entry systems with the
technology of:
- Elvox Due Fili
- Digibus
- Sound System or C.A. call
The entrance panels are supplied with a front plate and a
frame and are comprehensive of electronics and related add-
ons supplied separately to be selected depending on the type
of plant (Elvox Due Fili, Digibus, Sound System, c.a. call) and
the type of installation.
The instructions refer to mounting the entrance panel only.
For complete installation, connection and programming (for
electronic panels), please refer to the manual of the electronic
unit, camera or speech unit to be added:
For the DUE FILI system:
- Push-button electronic unit: 13F3 (audio), 13F5 (video)
- Electronic unit with alphanumeric keypad: 13F4 (audio),
13F7 (video)
- Audio speech unit: 6931.
For the DIGIBUS system:
- Push-button electronic unit: 1283 (audio), 1285 (video)
- Electronic unit with alphanumeric keypad: 1282 (audio),
1286 (video)
For the Sound System or C.A. system:
- Audio speech units: Art. 930A, 930C, 930D, 930F, 930G.
- Camera with Speech Unit: Art. 559A, 559B, 560A.
Additional components for Due Fili and Digibus
systems
The entrance panel is supplied ready for video door entry
systems and is to be implemented with the following items:
- Flush-mounted back box art. 9192 for entrance panels in
2 vertical modules or art. 9193 for entrance panels in 3
vertical modules.
Note: Back boxes 9192 and 9193 cannot be matched with
each other but only as follows: 9192 with 9192 or 9193
with 9193.
- Rainproof covers art. 1P21, 1P22, 1P23, 1P24 for en-
trance panels in 2 vertical modules or 1P31, 1P32, 1P33,
1P34 for entrance panels in 3 vertical modules
- Surface-mounted boxes with rainproof cover art. 1E21,
1E22, 1E23, 1E24 for entrance panels in 2 vertical mod-
ules or 1E31, 1E32, 1E33, 1E34 for entrance panels in 3
vertical modules.
- Push-button audio electronic unit Art. 13F3 (Due Fili) or
Art. 1283 (Digibus)
- Alphanumeric audio electronic unit Art. 13F4 (Due Fili) or
EN
Art. 1282 (Digibus)
- Push-button video electronic unit Art. 13F5 (Due Fili) or
Art. 1285 (Digibus)
- Alphanumeric video electronic unit Art. 13F7 (Due Fili) or
Art. 1286 (Digibus)
- Additional module with buttons: Art. 12TS with 4 buttons
(for entrance panels with a single row of keys) or Art. 12TD
with 8 buttons (for entrance panels with two rows of keys).
The same entrance panel can be preset for the audio elec-
tronic unit, in which case you need to remove the ring from
the back of the front plate, marked with number 1 in figure 6,
and in its place insert the cover for closing the lens, marked
with number 2 in figure 6, on the frame (B).
Additional components for Sound System and
C.A. call systems:
The entrance panel is preset for video entrance panel sys-
tems and is to be implemented with the following articles:
- Flush-mounted back box type 9192 for entrance panels in
2 vertical modules or type 9193 for entrance panels in 3
vertical modules.
Note: Back boxes type 9192 or 9193 cannot be matched
between them but only between: 9192 with 9192 or 9193
with 9193
- Video camera with speech unit type 559A or 559B or 560A
or speech unit type 930A, 930B, 930C, 930D, 930F or Art.
930G (fig. 1 shows how to insert the camera in the frame).
- Push-buttons type R200, R200/50 (R200/50 = package
with 50 push-buttons R200)
- LED for lighting name-tags type R260
- Diodes type 0002/994 (for "1+N wires" or without coaxial
cable).
- Rainproof covers type 1P21, 1P22, 1P23, 1P24 for en-
trance panels in 2 vertical modules or 1P31, 1P32, 1P33,
1P34 for entrance panels in 3 vertical modules
- Surface-mounted boxes with rainproof cover type 1E21,
1E22, 1E23, 1E24 for entrance panels in 2 vertical mod-
ules or 1E31, 1E32, 1E33, 1E34 for entrance panels in 3
vertical modules.
The same entrance panel can be preset for the sole external
speech unit; in this case remove the ring from the back of the
front plate (identified with number 1 in fig. 6); insert in its place
the cover for closing the lens (shown with number 2 in fig. 6)
in the frame "B", install the bracket "C" (using the screws sup-
plied) for the speech unit (see fig. 20, 22, 24).
Installing 1200 series panels in Due Fili or
Digibus systems.
- Install the flush-mounting back box (N) or the surface-
mounting back box (P) on the wall at a height of approx.
1.65m from the top edge of the box to the ground.
Note: The 1200 series panels can be expanded only hori-
zontally with supplementary entrance panels. In the case
of flush-mounting, the boxes are to be coupled using the
hooks supplied with the boxes (see Fig. 30).
- Secure the terminal block of the electronic unit under the
module holder frame with the screws provided.
- When flush-mounting on a wall:
- Secure the rainproof cover (O), if applicable, to the flush-
mounting box (N).
- Secure the frame (B) to the flush-mounting box (N) or to
the rainproof cover.
When surface-mounting on a wall:
- Secure the frame (B) to the surface-mounting back
box.
- Connect the terminal block of the electronic unit to the sys-
tem, following the wiring diagrams in the reference manual
depending on the type of system.
- Connect the electronic unit (S, T/U, V) to the terminal block
with the wiring in the top.
- Connect any additional modules used (fig. 31B, 31C).
They should be connected one after the other by means of
the wiring supplied with the modules, and finally connected
to the standard electronic unit by means of the wiring in its
lower section.
The connection of more than one additional module
may necessitate the use of an additional power supply
unit art. 6582 to power the LEDs lighting the signs.
- Insert the electronic unit and any additional modules in
the frames (for the additional modules Art. 12TS of push-
button entrance panels, use the insert supplied to hold
them together, see Fig. 31B).
- Insert the microphone into the seat over the frame (B) in
the lower right side, closing the cap, as shown in fig. 7
detail 1.
Note: On the electronic units for Digibus systems it is nec-
essary to take out or cut the rubber cap (existing on audio
speech units or cameras), taking care not to cut the wires
of the microphone (see fig.7).
- Do the programming, referring to the manual of the elec-
tronic unit.
- For audio door entry systems, on the back of the front plate
you need to take out the lens ring (E) and insert the cover
for closing the lens (D) (see fig. 6).
- Shut the entrance panel, fixing it to the frame using the
special key "P" supplied (see fig. 8).
Installing the 1200 series panels in systems
with an audio speech unit or camera with a
speech unit (Sound System or c.a. systems)
Installing flush-mounting entrance panels on a
wall
- Install the flush-mounting back box (N) on the wall at a
height of approx. 1.65m from the top edge of the box to
the ground
Note: The 1200 series panels can be expanded only hori-
zontally with additional panels, joining the flush-mounting
back boxes with the hooks supplied with the boxes (see
Fig. 30).
- In the case of audio door entry systems: secure the
bracket (C) at the top of the frame (B) with the screws in
the ready-made holes and secure the speech unit to the
bracket (see fig.20, 22)
- In the case of video door entry systems: secure the cam-
era (M) to the frame (B) as shown in fig. 1, 21, 23
- Insert the microphone into the seat over the frame (B)
closing the cap, as shown in fig. 7 detail 1.
- Secure the push-buttons (G) to the frame (B) as shown in
fig. 20, 21, 22, 23
- Secure the card for LED lighting (H) in its seat as shown in
fig. 20, 21, 22, 23
- Secure the rainproof cover (O) to the flush-mounting box
- Secure the frame to the flush-mounting box or to the rain-
proof cover
- For audio door entry systems, on the back of the front plate
you need to take out the lens ring "E" and insert the cover
for closing the lens "D" (see fig. 6)
- Connect the speech unit or the camera, push-buttons and
LED card to the system, following the wiring diagrams in
the reference manual depending on the type of system.
- Close the entrance panel, securing it to the frame with the
aid of a screwdriver (see fig. 8).
Installing surface-mounting entrance panels on
a wall
- Install the surface-mounting back box (P) on the wall at a
height of approx. 1.65m from the top edge of the box to the
ground.
Note: The 1200 series panels can be expanded only hori-
zontally with supplementary entrance panels.
- In the case of audio door entry systems: secure the
bracket (C) at the top of the frame (B) with the screws in
the ready-made holes and secure the speech unit to the
bracket (see fig. 24)
- In the case of video door entry systems: secure the cam-
era (M) to the frame (B) as shown in fig. 1, 25.
- Insert the microphone into the seat over the frame (B)
closing the cap, as shown in fig. 7 detail 1.
- Secure the frame to the surface-mounting back box
- Secure the card for LED lighting (H) in its seat as shown in
fig. 24, 25
- For entrance panels with only an audio speech unit, on the
back of the front plate you need to take out the lens ring
"E" and insert the cover for closing the lens "D" (see fig.
6)
- Connect the speech unit or the camera, push-buttons and
LED card to the system, following the wiring diagrams in
the reference manual depending on the type of system.
- Shut the entrance panel, fixing it to the frame using the
special key "P" supplied (see fig. 8).