5. Cut positive (+) cable to the length required to
reach the AUX terminal of the circuit breaker
(FIGS. 16-2 and 17-3), without putting strain
on the connection. Install copper lug (Kit item)
(FIGS. 17-1 and 17-2). Then, connect to AUX
terminal on 150A circuit breaker (FIGS. 16-2
and 17-3).
6. Cut remaining positive (+) cable long enough
to reach from the circuit breaker BAT terminal
to the positive (+) battery terminal (FIGS. 16-2
and 17-3) without putting strain on the con-
nection. Install copper lugs (Kit item) on both
ends of cable (FIGS. 17-1 and 17-2). Then,
connect cable to BAT terminal on 150A circuit
breaker (FIGS. 16-2 and 17-3) and positive
(+) terminal on battery (FIG. 16-2).
7. Cut negative (-) cable to length required to
reach negative (-) battery terminal (FIG. 16-
2) without putting strain on the connection.
Install copper lug (Kit item) (FIGS. 17-1 and
17-2). Then, connect cable to negative (-)
terminal on battery (FIG. 16-2).
LIFT CORPORATION Sht. 17 of 52 DSG#
ROUTING POWER CABLES - Continued
HEATSHRINK
POWER CABLE
(BARE WIRE END)
PLACING COPPER LUG & HEATSHRINK
TUBING ON POWER CABLE
TYPICAL POWER CABLE WITH
CONNECT LONG POS (+)
CABLE FROM LIFTGATE
POWER CABLE CONNECTIONS
M-16-32
Rev. B Date: 09/21/18
COPPER LUG
TUBING
FIG. 17-1
COPPER LUG INSTALLED
FIG. 17-2
CONNECT SHORT POS
(+) CABLE TO BATTERY
TO 150A CIRCUIT BREAKER
FIG. 17-3