Alarms; Door Ajar; Power Failure; Temperature Alarm - AGA marvel ML24RF Instrucciones De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Alarms:

The control will alert you to conditions that could adversely
affect the performance of the appliance.

Door Ajar

Door ajar -
If the door is open, or not closed prop-
erly, for more than 5-minutes the System Status OK
indicator will turn-off, the "Door Ajar" indicator will flash,
and a tone will sound every 60 seconds. Additionally,
an "ALARM RESET" indicator will be displayed below
the "On/Off" keypad. This alarm condition can be reset
by closing the door or momentarily pressing the "On/
Off" keypad, (i.e.-if you are cleaning the storage com-
partment, etc.). The alarm will recur in 5-minutes if the
alarm condition persists.

Power Failure

Power failure -
If power to the appliance is inter-
rupted the System Status indicator will turn-off and
the "Power Failure" indicator will flash. Additionally, an
"ALARM RESET" indicator will be displayed below the
"On/Off" keypad. No audible tone will sound. This alarm
condition can be reset by momentarily pressing the
"On/Off" keypad. If this alarm occurs, it is recommend-
ed that you check the condition of any perishables,
even if the appliance is operating normally and the tem-
perature has recovered, as prolonged power outages
could result in excessive temperature excursions which
may spoil perishables.
USING YOUR ELECTRONIC CONTROL
ALARM RESET
ALARM RESET
Temp

Temperature alarm -

temperature exceeds 10°F from set-point for more than
a 1-hour duration, the System Status indicator will turn
off, the "Temp" indicator will flash, and an audible tone
will sound every 60-seconds. Additionally, an "ALARM
RESET" indicator will be displayed below the "On/Off"
keypad. This alarm condition can be reset by momen-
tarily pressing the "On/Off" keypad. If this alarm occurs
it is recommended that you check the condition of your
stored contents, even though the appliance is operating
normally and the temperature has recovered, as pro-
longed temperature excursions could spoil perishables.
NOTE
Multiple alarms are possible, i.e.- "Door Ajar" for a pro-
longed period may trigger a "Temp" alarm, in which case
both "Door Ajar" and "Temp" indicators will activate.
14
ALARM RESET
If the storage compartment
Door Ajar
Temp

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ml24ri

Tabla de contenido