GYS Powerduction Heat controler Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
Translation of the original instructions
It is advisable to point the heater in the opposite direc-
tion to the pyrometer location (see photo opposite).
Connecting diagram
Security
Automation
Voltage
Emissivity
Pyrometer
Power
Switch setting
14
POWERDUCTION HEAT CONTROLER
dry contact
this connector allows you to connect a pyrometer to measure voltage or to
connect an external switch (which replaces the pedal)
This potentiometer allows to modify the setting (thanks to the screw) and to
refine the temperature measurement according to the emissivity of the part to
be heated.
this connector is used to connect the pyrometer (e.g. pyrometer - ref 064119)
1
sif ON cancellation of thermocouple 2 measurement
2
if ON cancellation of thermocouple 1 measurement
3 et 4
offline
5
if ON activation of an OFFSET for the initial display at 100°C (button 5 has priority over
all the others) (do not use for a thermocouple measurement)
6
if ON and switch 5 OFF initial display at 0 (do not use for thermocouple measurement)
7 et 8
if ON activation of the footswitch connected to the REMOTE input
heating direction
{
If both are OFF, the highest
measurements is displayed.
EN
pyrometer

Publicidad

Tabla de contenido
loading

Tabla de contenido