GYS Powerduction Heat controler Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
Translation of the original instructions
OPERATION WITH PYROMETER ANALOG OUTPUT (not supplied)
Use a pyrometer sensor with an analog output directly on the product connectors (to be adapted according to the
datasheet of the pyrometer used)
Example of a current measuring pyrometer
In this case, the value of the shunt R resistance on U T° must be adapted according to the setpoint and the desired
accuracy (10 mV per Degree).
Correspondence table
Voltage U T°
1 V
2 V
3 V
4 V
4.5 V
MANUAL MODE (FIG II & III)
For an optimal use of the product, it is recommended to set the power between 30 and 50%.
To return to the «outdoor temperature control» mode:
1. Press and hold the heating enable button (9) for 5 seconds.
2. The button blinks every second and «rEG» is displayed.
The button on the lance (10) and the pneumatic pedal (11) are deactivated in this mode.
To set and then activate the heater :
1. Adjust the control setpoint: Press the adjustment buttons (14).
The regulation setpoint varies from 80°C to 350°C (default value at 250°C) in 10°C steps. It is displayed for one
second.
POWERDUCTION HEAT CONTROLER
Temperature in Celsius
0°C
100°C
200°C
300°C
350°C
Temperature in Fahrenheit
32°F
210°F
390°F
570°F
660°F
EN
15

Publicidad

Tabla de contenido
loading

Tabla de contenido