8 Troubleshooting
Fault
‡ Motor does not start
‡ Motor does not run in
automatic mode
‡ Mirka 415 M: The acoustic
warning sounds (Reduced
suction power)
‡ No suction power during
wet cleaning
‡ Voltage fluctuations
Cause
> Fuse of the mains socket has
blown.
> Overload protection switch
has tripped.
> Self-acting carbon brush is
worn.
> Power tool is defective or not
connected properly.
> The power rating of the
electrical tool is too low.
> Suction power selected with
suction power control is too
low.
> Hose diameter and switch
position do not correspond.
> Clogged suction hose/nozzle. •
> Filter bag is full.
> Filter element is clogged.
> Tank is full. (Float closes the
suction opening).
> Impedance of power supply is
too high.
Remedy
Connect mains fuse.
Switch off the vacuum
cleaner and allow it to cool
for approx. 5 minutes. If the
cleaner cannot be started
again, contact the service
department.
Have carbon brushes changed
by the Service.
Check that the power tool
works or that the plug is
inserted correctly.
Note that minimum power
rating is P>40W
Set suction power in
accordance with section 4.2.3.
„Setting suction power".
Set correct switch position for
hose diameter.
Clean suction hose/nozzle
See section 7.2.2 „Replacing
filter bag".
See section 4.5 „Cleaning
filter element" and 7.2.4
„Replacing filter element".
Switch off the cleaner. Empty
the tank.
Connect the cleaner to
another socket closer to the
fuse box. Voltage fluctuations
over 7% should not occur if
the impedance at the transfer
point is
0.15
.
Mirka 412 / 415 / 415 M