LIFT CORPORATION Sht. 1 of 42 DSG#
INSTRUCTION, TUK-A-WAY HAND PUMP KIT
Installing and maintaining a liftgate can expose you to chemicals, including lead, which are known
to the State of California to cause cancer and birth defects or other reproductive harm. To minimize
exposure, install and maintain liftgate in a well-ventilated area and wear proper Personal protective
equipment (PPE). For more information go to www.P65Warnings.ca.gov.
NEEDLE VALVE,
ADJUSTABLE, SAE #6
P/N 906739-01
QTY. 1
ELBOW, 90°, 1/4"- 3/8"
P/N 251853
QTY. 2
POP RIVET, 3/16" X 7/16" LG.
P/N 904005-1
QTY. 2
Estas instrucciones están disponibles en español a partir de la última página.
Estas instrucciones están disponibles en español a partir de la página 22.
© MAXON Lift Corp. 2020
INSTALLATION
KIT P/N 297117-01
WARNING
!
ADAPTER,
#6 O-RING/1/4" SWIVEL
P/N 906814-01
QTY. 1
ELBOW, SAE #6
O-RING, SWIVEL
P/N 906708-01
QTY. 1
SPRING CLIP HOLDER
P/N 227681
QTY. 2
M-16-16
ADAPTER,
1/4" O-RING/1/4" NPT
P/N 906756-01
QTY. 1
ELBOW, ORFS/ORB 6-4
P/N 906818-01
QTY. 1
HANDLE, HAND PUMP
P/N 251407-02
QTY. 1
Rev. A Date: 04/22/20
TEE, SAE #6
P/N 906745-01
QTY. 1
HAND PUMP,
SAE #4 PORTS
P/N 266588-01
QTY. 1
BRACKET,
HAND PUMP MOUNT
P/N 268076-01
QTY. 1

Publicidad

loading

Resumen de contenidos para Maxon 297117-01

  • Página 1 HAND PUMP MOUNT QTY. 2 QTY. 2 QTY. 1 P/N 268076-01 QTY. 1 Estas instrucciones están disponibles en español a partir de la última página. Estas instrucciones están disponibles en español a partir de la página 22. © MAXON Lift Corp. 2020...
  • Página 2 P/N 210742-01 1/4”-20 X 1-3/4” LG, GR8 P/N 905322-01 QTY. 1 P/N 900025-7 QTY. 1 QTY. 2 HAND PUMP OPERATION DECAL HOSE , LP, 3/8” X 17” LG. P/N 295120-01 P/N 251855-09 QTY. 1 QTY. 1 © MAXON Lift Corp. 2020...
  • Página 3 BATTERY POST cables from battery (FIG. 3-2). Rein- stall nuts on negative (-) and positive (+) battery terminals. DISCONNECTING BATTERY POWER FIG. 3-2 3. Unbolt and remove pump cover (FIG. 3-3). UNBOLTING PUMP COVER FIG. 3-3 © MAXON Lift Corp. 2020...
  • Página 4 HOLE PATTERNS FOR MOUNTING BRACKET FIG. 4-1 5. Measure, mark, and drill 2 holes for spring clips (FIG. 4-2). 9-1/2” HOLE DIA. .196” MAX .192” MIN (2 PLACES) 2-1/4” 1-3/8” HOLE PATTERNS FOR SPRING CLIPS FIG. 4-2 © MAXON Lift Corp. 2020...
  • Página 5 7. Rivet the 2 spring clips to mounting plate (FIG. 5-2). RIVETING SPRING CLIPS FIG. 5-2 8. Place handle (Kit item) in the spring clips as shown in FIG. 5-3. STOWING HANDLE IN SPRING CLIPS FIG. 5-3 © MAXON Lift Corp. 2020...
  • Página 6 9. Bolt hand pump (Kit item) to mounting bracket (FIG. 6-1). BOLTING ON HAND PUMP FIG. 6-1 CAUTION Torque the connectors to 13-15 lb-ft. Do not overtighten. 10. Connect O-ring adapter (Kit item) and 90°elbow (Kit item) to hand pump (FIG. 6-2). © MAXON Lift Corp. 2020...
  • Página 7 (FIG. 7-2). Then, con- CONNECTING ELBOW, nect branch tee (Kit item) to needle valve NEEDLE VALVE & TEE as shown in FIG. 7-2. Do not tighten con- FIG. 7-2 nectors until later in this procedure. © MAXON Lift Corp. 2020...
  • Página 8 HP HOSE in this procedure. 90° ELBOW CONNECTING HIGH PRESSURE HOSE FIG. 8-2 16. Remove plug from hand pump port on pump manifold (FIG. 8-3). REMOVING PLUG FROM HAND PUMP PORT FIG. 8-3 © MAXON Lift Corp. 2020...
  • Página 9 CONNECTING ADAPTER AND ELBOW TO HAND PUMP PORT FIG. 9-1 18. Connect 90° elbow (Kit item) to hand pump port (FIG. 9-2). Position elbow as shown. CONNECTING ELBOW FIG. 9-2 © MAXON Lift Corp. 2020...
  • Página 10 (FIG. 10-1). CONNECTING LOW PRESSURE HOSE FIG. 10-1 20. Tie the hand pump hoses together with plastic tie (Kit item) (FIG. 10-2). ATTACHING PLASTIC TIE FIG. 10-2 © MAXON Lift Corp. 2020...
  • Página 11 HOSE ASSEMBLY ELBOW NEEDLE VALVE HAND PUMP TIGHTENING FITTINGS FIG. 11-1 ITEM DESCRIPTION TORQUE VALUE SAE#6 O-RING (MALE) 22-24 lb-ft. SAE#6 FACE SEAL (FEMALE) 25-27.5 lb-ft. SAE#4 O-RING (MALE) 13-15 lb-ft. TORQUE VALUES TABLE 11-1 © MAXON Lift Corp. 2020...
  • Página 12 22. Close needle valve by turning knob fully clockwise (FIG. 12-1). Then, close hand pump pressure release valve, by turning valve clockwise with handle (FIG. 12-1). NEEDLE VALVE CLOSING NEEDLE VALVE & HAND PUMP RELEASE VALVE FIG. 12-1 © MAXON Lift Corp. 2020...
  • Página 13 (FIG. 13-2). Turn release valve fully clockwise to stop platform from lowering (FIG. 13-2). OPENING/CLOSING RELEASE VALVE FIG. 13-2 PLATFORM LOWERING PLATFORM WITH HAND PUMP FIG. 13-3 © MAXON Lift Corp. 2020...
  • Página 14 Do not use for repeated loading and un- loading of vehicle. 26. Open the needle valve by turning knob fully counterclockwise (FIG. 14-2). OPENING NEEDLE VALVE FIG. 14-2 © MAXON Lift Corp. 2020...
  • Página 15 27. Use the control switch to LOWER platform to the ground (FIG. 15-1). LOWERING PLATFORM TO GROUND WITH CONTROL SWITCH FIG. 15-1 28. Unfold platform and fl ipover (FIG. 15-2). FLIPOVER PLATFORM UNFOLDING PLATFORM & FLIPOVER FIG. 15-2 © MAXON Lift Corp. 2020...
  • Página 16 FIG. 16-1 30. Repeat step 27 and step 29 until all air has been bled from the system. 31. Check hydraulic fl uid level in the pump reservoir. Refer to the Maintenance Manual for detailed instructions. © MAXON Lift Corp. 2020...
  • Página 17 FIG. 17-2. ATTACHING DECAL FIG. 17-2 34. Bolt on the pump cover as shown in FIG. 17-3. Torque the bolts (cap screws) to 10 - 14 lb.- in. BOLTING ON PUMP COVER FIG. 17-3 © MAXON Lift Corp. 2020...
  • Página 18 Do not use for continuous operation. 2. To use hand pump for backup operation, close the needle valve by turning knob fully clockwise (FIG. 18-2). CLOSING NEEDLE VALVE FIG. 18-2 © MAXON Lift Corp. 2020...
  • Página 19 TO LOWER PLATFORM FIG. 19-1 LOWERING PLATFORM FIG. 19-2 4. Use the handle with hand pump to raise the platform (FIGS. 19-3 & 19-4). RAISING PLATFORM WITH HAND PUMP FIG. 19-3 PLATFORM RAISING PLATFORM FIG. 19-4 © MAXON Lift Corp. 2020...
  • Página 20 LIFT CORPORATION Sht. 20 of 42 DSG# Rev. A Date: 04/22/20 5. For normal Liftgate operation with power unit, open the needle valve by turning knob fully counterclockwise (FIG. 20-1). OPENING NEEDLE VALVE FOR NORMAL OPERATION FIG. 20-1 © MAXON Lift Corp. 2020...
  • Página 21 (FIG. 21-1). STOWING PUMP HANDLE FIG. 21-1 7. Bolt on the pump cover as shown in FIG. 21-2. Torque the bolts (cap screws) to 10 - 14 lbs.- in. BOLTING ON PUMP COVER FIG. 21-2 © MAXON Lift Corp. 2020...
  • Página 22: Instrucciones, Instalación Del Kit De Bomba Manual Tuk-A-Way

    SOPORTE DE MONTAJE REMACHES ABRAZADERA MANIVELA DE LA DE LA BOMBA MANUAL DE 3/16” X 7/16” LG. DE RESORTE BOMBA MANUAL N/P 268076-01 N/P 904005-1 N/P 227681 N/P 251407-02 CANT. 1 CANT. 2 CANT. 2 CANT. 1 © MAXON Lift Corp. 2020...
  • Página 23 DE 8” (120 LB) N/P 900025-7 N/P 210742-01 N/P 905322-01 CANT. 2 CANT. 1 CANT. 1 ETIQUETA DE OPERACIÓN PARA LA BOMBA MANGUERA, LP, 3/8” X 17” LG. MANUAL N/P 251855-09 N/P 295120-01 CANT. 1 CANT. 1 © MAXON Lift Corp. 2020...
  • Página 24 Coloque nuevamente la tuerca negativa (-) y positiva (+) en las terminales. DESCONECTAR LA ENERGÍA DE LA BATERÍA FIG. 24-2 3. Destornille y retire la cubierta de la bomba (FIG. 24-3). DESTORNILLAR LA CUBIERTA DE LA BOMBA FIG. 24-3 © MAXON Lift Corp. 2020...
  • Página 25 (FIG. 25-2). 9-1/2” [24 cm] DIÁMETRO DE .196” [5 mm] MÁX. .192” [4.9 mm] MÍN. (2 LUGARES) 2-1/4” [5.7 cm] 1-3/8” [3.4 cm] PATRÓN DE AGUJEROS PARA LAS ABRAZADERAS CON RESORTE FIG. 25-2 © MAXON Lift Corp. 2020...
  • Página 26 8. Sitúe la manivela de la bomba manual (artículo del kit) en las abrazaderas con resorte como se muestra en la FIG. 26-3. GUARDAR LA MANIVELA DE LA BOMBA EN LAS ABRAZADERAS DE RESORTE FIG. 26-3 © MAXON Lift Corp. 2020...
  • Página 27: Precaución Fig

    Aplique un torque de 13-15 lb-ft [17.6 - 20.3 Nm] a los conectores. No apriete en exceso. 10. Conecte el adaptador con junta tórica y el codo de 90° (artículos del kit) a la bomba manual (FIG. 27-2). © MAXON Lift Corp. 2020...
  • Página 28 (artículo del kit) al codo giratorio (FIG. 28-2). Luego, conecte el Te macho (artículo del kit) a la válvula de aguja como se muestra en la FIG. 28-2. No apriete los conectores hasta que se le indique después en este procedimiento. © MAXON Lift Corp. 2020...
  • Página 29 CONECTAR LA LÍNEA DE PRESIÓN ALTA FIG. 29-2 16. Retire el tapón del puerto en la bomba manual en el múltiple de la bomba (FIG. 29-3). RETIRAR EL TAPÓN DEL PUERTO DE LA BOMBA MANUAL FIG. 29-3 © MAXON Lift Corp. 2020...
  • Página 30 AL PUERTO DE LA BOMBA MANUAL FIG. 30-1 18. Conecte el codo de 90° (artículo del kit) al puerto de la bomba manual (FIG. 30-2). Posicione el codo tal como se muestra. CONECTAR EL CODO FIG. 30-2 © MAXON Lift Corp. 2020...
  • Página 31 (FIG. 31-1). CONECTAR LA MANGUERA DE PRESIÓN BAJA FIG. 31-1 20. Junte las mangueras de la bomba con el cintillo de plástico (artículo del kit) FIG. 31-2. ADJUNTAR EL CINTILLO DE PLÁSTICO FIG. 31-2 © MAXON Lift Corp. 2020...
  • Página 32: Descripción

    JUNTA TÓRICA SAE #6 (MACHO) 22-24 lb-ft [29.8 - 32.5 Nm] SELLO FRONTAL SAE #6 (HEMBRA) 25-27.5 lb-ft [33.9 - 37.3 Nm] JUNTA TÓRICA SAE #4 (MACHO) 13-15 lb-ft [17.6 - 20.3 Nm] VALORES DE TORQUE TABLA 32-1 © MAXON Lift Corp. 2020...
  • Página 33 (FIG. 33-1). VÁLVULA DE AGUJA CERRAR LA VÁLVULA DE AGUJA Y LA VÁLVULA DE ALIVIO DE PRESIÓN DE LA BOMA MANUAL FIG. 33-1 © MAXON Lift Corp. 2020...
  • Página 34 (FIG. 34-2). ABRIR/CERRAR LA VÁLVULA DE ALIVIO FIG. 34-2 PLATAFORMA DESCENDER LA PLATAFORMA CON LA BOMBA MANUAL FIG. 34-3 © MAXON Lift Corp. 2020...
  • Página 35 No la utilice repetidamente para cargar y descargar el vehículo. 26. Abra la válvula de aguja girando completamente la perilla en sentido contrario a las manecillas del reloj (FIG. 35-2). ABRIR LA VÁLVULA DE AGUJA FIG. 35-2 © MAXON Lift Corp. 2020...
  • Página 36 DESCENDER LA PLATAFORMA HASTA EL SUELO CON EL INTERRUPTOR DE CONTROL FIG. 36-1 28. Despliegue la plataforma y la rampa abatible (FIG. 36-2). RAMPA ABATIBLE PLATAFORMA DESPLEGAR LA PLATAFORMA Y LA RAMPA ABATIBLE FIG. 36-2 © MAXON Lift Corp. 2020...
  • Página 37 30. Repita el paso 27 y el paso 29 hasta que todo el aire haya sido purgado del sistema. 31. Verifi que el nivel de fl uido hidráulico en el depósito de la bomba. Consulte el Manual de Mantenimiento para las instrucciones detalladas. © MAXON Lift Corp. 2020...
  • Página 38 34. Atornille la cubierta de la bomba como se muestra en la FIG. 38-3. Aplique un torque de 10-14 lb-in [1.1-1.5 Nm] en los pernos (tornillos con cabeza). ATORNILLAR LA CUBIERTA DE LA BOMBA FIG. 38-3 © MAXON Lift Corp. 2020...
  • Página 39 2. Para usar la bomba manual en una operación de respaldo, cierre la válvula de aguja al girar la perilla completamente hacia las manecillas del reloj (FIG. 39-2). CERRAR LA VÁLVULA DE AGUJA FIG. 39-2 © MAXON Lift Corp. 2020...
  • Página 40 DESCENDER LA PLATAFORMA FIG. 40-2 4. Utilice la manivela en la bomba manual para elevar la plataforma (FIGS. 40-3 y 40-4). ELEVAR LA PLATAFORMA CON LA BOMBA MANUAL FIG. 40-3 PLATAFORMA ELEVAR LA PLATAFORMA FIG. 40-4 © MAXON Lift Corp. 2020...
  • Página 41 (FIG. 41-1). ABRIR LA VÁLVULA DE AGUJA PARA LA OPERACIÓN NORMAL FIG. 41-1 © MAXON Lift Corp. 2020...
  • Página 42 7. Atornille la cubierta de la bomba como se muestra en la FIG. 42-2. Aplique un torque de 10 - 14 lb- in [13.5 - 19.0 Nm] a los pernos (tornillos con cabeza). ATORNILLAR LA CUBIERTA DE LA BOMBA FIG. 42-2 © MAXON Lift Corp. 2020...