LIFT CORPORATION Sht. 11 of 42 DSG#
Hydraulic lines and fi ttings must be torqued as shown in FIG. 11-1
and TABLE 11-1.
21. Reposition elbows, tee and hoses
as required (FIG. 11-1). Then,
torque the fi ttings as shown in
FIG. 11-1 and TABLE 11-1.
ITEM
1
SAE#6 O-RING (MALE)
2
SAE#6 FACE SEAL (FEMALE)
3
SAE#4 O-RING (MALE)
© MAXON Lift Corp. 2020
CAUTION
HOSE
ASSEMBLY
ELBOW
2
1
TEE
2
NEEDLE
VALVE
TIGHTENING FITTINGS
DESCRIPTION
TORQUE VALUES
TABLE 11-1
M-16-16
1
2
2
FIG. 11-1
TORQUE VALUE
22-24 lb-ft.
25-27.5 lb-ft.
13-15 lb-ft.