LIFT CORPORATION Sht. 3 of 42 DSG#
1. Lower the platform to a comfortable work
height (FIG. 3-1). Then, use jack stand
under the lift frame to support the Liftgate
(FIG. 3-1). Refer to Operation Manual for
detailed operating instructions.
!
WARNING
To prevent personal injury
and equipment damage, make
sure power is disconnected
from Liftgate while installing
hydraulic electrical parts.
2. Disconnect power to the pump by dis-
connecting negative (-) and positive (+)
cables from battery (FIG. 3-2). Rein-
stall nuts on negative (-) and positive
(+) battery terminals.
3. Unbolt and remove pump cover
(FIG. 3-3).