9. Open the Live View page in the web browser and check the quality of the image.
10. On the Focus page, click Fine-tune focus automatically and wait until automatic fine
tuning is completed.
11. Click Enable iris. If the button is inactive the iris is already enabled.
12. If needed, make further adjustments under the Advanced tab. See the online help for
more information.
Replacing the lens
It is possible to use optional lenses for the Axis product.
To replace the lens:
1. Disconnect the iris cable.
2. Unscrew the standard lens.
3. Attach and screw on the new lens.
To change the iris configuration:
1. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the
current configured iris type.
2. Click Edit.
3. Select the installed iris lens from the drop-down list and click OK.
To change the iris configuration for P-iris lenses not listed in the drop-down list:
1. Download the iris configuration file from www.axis.com
2. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the
current configured iris type.
3. In Iris configuration: Click Edit.
4. Go to the Upload tab.
5. Click Browse and select the configuration file.
6. Click Upload. The installed iris lens should now be included in the Iris Selection
drop-down list.
7. Select the installed iris lens from the drop-down list and click OK.
Note
• If you select a DC iris configuration file for a P-iris lens, an error message will appear
below the iris configuration type in the Camera Settings page. For custom DC Iris lenses,
select Generic DC Iris option.
• There is no need to restart the product after changing the lens. However, the product must
be restarted if you are interchanging between a P-iris, DC-Iris or fixed/manual iris lens. In
order to set the focus and position the lens, the product must be connected to the network.
AXIS Q1615-E Network Camera
23