Descargar Imprimir esta página

Elvox 6600 Serie Manual Para El Conexionado Y El Uso página 7

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
I N T R O D U C T I O N / I N S T A L L A T I O N
INSTALLATION OF TYPE 6611 WITH BRACKETS TYPE R660
Install the video interphone away from sources of light and heat.
- Make a 120x120mm (nearly) hole in the plasterboard wall at 1.40 m
high from the floor to the lower border.
- Fix the bracket to the video interphone as indicated in figure, keeping
the cursors well aligned to the video interphone sides.
- Carry out the terminal block connections (see wiring diagram).
- Insert the video interphone inside the wall in plasterboard.
- By screwing, the cursors should get aligned orthogonally to the video
interphone.
- Insert the side grids, paying attention that the one with the slot for the
microphone must be inserted on the right.
INSTALLATION OF TYPE 6711
Install the video interphone away from sources of light and heat.
- Fix the monitor fixing plate at 1,40m. from the ground level to the lower
border.
- Connect the terminal block. (see wiring diagram)
- Insert the video interphone according to the 1 and 2 arrow direction
- To remove the video interphone from the plate hook, operate with a
screw driver on the security lock (placed on the upper side and behind
the video interphone), and remove it according to the 3 and 4 arrow di-
rection.
Surface wall-mounting
version
Fig. 2A
INTSLLATION OF TYPE 661C
- Fix the monitor support to the wall.
- Connect the terminal block (see wiring diagrams).
- Hook the stud to the support.
7/32
141mm
1
2
Table version
141mm
Fig. 2C
GB
125mm
4
3
Fig. 2B
125mm

Publicidad

loading