Weber Q Manual Del Usuario página 21

Ocultar thumbs Ver también para Q:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DANGER
Do not use an open fl ame to
check for gas leaks. Be sure
there are no sparks or open
fl ames in the area while you
check for leaks. Sparks or open
fl ames will result in a fi re or
explosion, which can cause
serious bodily injury or death
and damage to property.
1)
Mix soap and water.
2)
Turn on the cylinder valve by turning
cylinder valve handwheel counter-
clockwise.
3)
Check for leaks by wetting the fi tting with
the soap and water solution and watching
for bubbles. If bubbles form, or if a bubble
grows, there is a leak.
If there is a leak, turn off the gas and tighten
the fi tting. Turn the gas back on and recheck
with the soap and water solution.
If leak does not stop, Contact the Customer
Service Representative in your area using the
contact information on our web site. Log onto
www.weber.com
®
. Do not use the barbecue.
4)
When leak checking is complete, turn
gas supply OFF at the source and rinse
connections with water.
To perform leak checks: open cylinder valve
by turning the cylinder valve hand-wheel
counterclockwise.
WARNING: Do not ignite
burners when leak checking.
Check for leaks by wetting the connections
with the soap and water solution and watching
for bubbles. If bubbles form or if a bubble
grows, there is a leak.
Check:
A) VALVE TO-REGULATOR CONNECTIONS.
WARNING: If there is a leak at
connection (1) turn OFF the gas.
DO NOT OPERATE THE GRILL.
Contact the Customer Service
Representative in your area
using the contact information
on our web site. Log onto www.
weber.com
.
®
Check:
B) REGULATOR TO PROPANE CYLINDER
CONNECTION.
GAS INSTRUCTIONS
3.)
2.)
A.)
B.)
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Q 200Q 220

Tabla de contenido