Descargar Imprimir esta página

Samson 353120.300 Manual Del Usuario página 3

Bomba neumatica de aceite pumpmaster 2, ratio 3:1

Publicidad

Repair and cleaning procedure / Procedimientos de reparación y limpieza
EN
WARNING
B
efore starting any kind of maintenance or repair
disconnect the compressed air supply and open a
downstream valve to relieve the oil pressure
EN
Unscrew the suction tube. Be careful not to damage O-ring (24).
Remove pin (14) to separate the lower part of the pump (see fig. 6).
Remove screws (22) and pull the air motor dolly to remove
it. The air motor parts will be accessible.
Replace parts (18) and (15) if required.
Clean and inspect the parts carefully, and replace any
damaged parts.
E
Desenrosque el tubo de succión con cuidado de no dañar la
junta de unión (24).
Quite el pasador (14) para separar la parte inferior de la
bomba (ver figura 6).
Destornille los tornillos (22) y tire de la cazoleta hacia arriba
de forma que quedarán todas las piezas del cuerpo motor de
aire al descubierto.
Sustituya las piezas (18) y (15) si fuera necesario.
Limpie o sustituya las piezas deterioradas.
EN
Follow the procedures described in the "Air motor" procedure.
Pull the air valve assembly (6).
CAUTION: The air valve can only be assembled in a one position.
Do not force the parts together, they snap neatly into place
when correctly oriented.
Attach the shaft (13) to a rubber-covered-clamp vice.
Take out the stem bolt.
CAUTION: The threads have a non-permanent sealant that has
to be applied again when re-assembling the pump. Use
Loctite #242 or equivalent.
Be careful not to damage the O-ring (8) in the air pass cap (7).
Parts (9), (10), (11) and (12) are freed and ready to be repla-
ced and/or cleaned.
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533
E
,
a
reparación
válvula de salida para soltar la presión del aceite
Air motor / Motor de aire
Interver set / Conjunto inversor
ATENTION
ntes de empezar cualquier tipo de mantenimiento o
,
desconecte el aire de alimentación y accione la
21
22
24
6
7
8
9
10
11
12
13
14
41
18
15
40
18
19
18
Fig. 5
Fig. 6
3
R. 03/12 835 809

Publicidad