Migatronic PI 500 ROBO Guía De Usuario página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Special functions
Exit from the USER menu
Open/Close the gas valve in order to purge the torch,
check the gas bottle and pressure reducer. Press "A"
to Open/Close the gas. Exiting the USER menu will close the gas
anyway.
Calibration of gas flow at 10 and 20 litres by means of
flowmeter (81010000).
Submenu for MMA procediment
Exit from submenu
Value of Hot Start
Value of Arc Power
Submenu for wire feeder
Exit from submenu
Active control of CWF
0 = no CWF (default)
1 = at least one CWF
Submenu containing different options
Exit from submenu
Programs LOCK
0 = unlocked (default setting)
1 = locked P3 to P64
2 = locked P1 to P64
Panel LOCK
0 = unlocked (default setting)
1 = locked
2 = locked (as mode 1)
2-times option for torch trigger
0: return to welding current by step. (default)
1:
return to welding current by slope up
Press / Release
Press / Release
0
By STEP
1
By SlopeUP
15
4-times option for torch trigger
Permit to define 6 different ways to control the
torch trigger when the machine is set as 4Times stroke (Lift
or HF). For detailed description of different behaviours see
the following diagrams. Select a value in the range 0...5
(1=default setting).
Press / Release
Press / Release
Press / Release
Keep
start current
Press / Release
Keep
start current
Press / Release
Keep
start current
Press / Release
Note: The start current is disabled in
slope-up period is set at 0.
Dynamic Oxide Control
0 =
disabled
1 =
enabled (default setting)
Remote Control Option
Welding current can be controlled up to previous
SET or to MAX. External reference voltage can be 0-10V or
0-5V (Condition 2 & 3 presents lower resolution)
0 = 0-10V  Imin to ISET (default)
1 = 0-10V  Imin to IMAX
2 = 0-5V
 Imin to ISET
3 = 0-5V
 Imin to IMAX
Torch Remote Control
Makes it possible to control how the control unit on
the handle is used when torch adjustment is enabled (
0 = Setting the current reference (factory default).
1 = Enabling/disabling TIG-A-Tack (the TIG-A-Tack button is
disabled). The control unit is handled as follows:
Steps 1-3:
TIG-A-Tack is enabled
Steps 4-7:
The trigger is disabled
Steps 8-10: TIG-A-Tack is disabled
Saves all program settings in an SD card file. Insert an SD card
in the machine (same procedure as for SW update).
Loads program settings from SD card. Use P.SA. to save
program settings.
All the above settings will not be changed during reset to factory
settings.
Stop when key is released
Keep
final current
0
Stop when key is released
Stop when
slope completed
1
Stop when
slope completed
2
3
Stop when key is released
Stop when
slope completed
4
Stop when key is released
Keep
final current
5
3
,
4
and
if
5
).

Publicidad

Tabla de contenido
loading

Tabla de contenido